Szczegóły publikacji

Opis bibliograficzny

Ultrasensitive determination of tungsten(VI) on pikomolar level in voltammetric catalytic adsorptive catechol-chlorate(V) system / Robert PIECH, Anna BUGAJNA, Sebastian Baś, Władysław W. KUBIAK // Journal of Electroanalytical Chemistry ; ISSN  1572-6657 . — 2010 — vol. 644 iss. 1, s. 74–79. — Bibliogr. s. 78–79, Abstr.

Autorzy (4)

Słowa kluczowe

mercury film electrodestrace analysistungstencatalytic adsorptive stripping voltammetrychlorate(V)catechol

Dane bibliometryczne

ID BaDAP51688
Data dodania do BaDAP2010-05-11
Tekst źródłowyURL
DOI10.1016/j.jelechem.2010.04.003
Rok publikacji2010
Typ publikacjiartykuł w czasopiśmie
Otwarty dostęptak
Czasopismo/seriaJournal of Electroanalytical Chemistry

Abstract

The renewable mercury film electrode, applied for the determination of tungsten(VI) ultra traces using differential pulse catalytic adsorptive cathodic stripping voltammetry (DP CAdSV) with presence of catechol as a ligand and chlorate(V) is presented. The calibration graph obtained for W(VI) is linear from 0.025 nM (4.5 ng L-1) to 130 nM (23.9 μg L-1) for a preconcentration time of 30 s, with correlation coefficient of 0.9989. For the renewable mercury electrode (Hg(Ag)FE) with a surface area of 4.4 mm2 the detection limit for a preconcentration time of 60 s is as low as 0.2 ng L-1. The repeatability of the method at a concentration level of the analyte as low as 0.09 μg L-1, expressed as RSD is 3.1% (n = 5). The proposed method was successfully applied and validated by studying the certified reference material CTA-VTL-2 and simultaneously recovery of W(VI) from spiked water samples.

Publikacje, które mogą Cię zainteresować

artykuł
#104526Data dodania: 31.3.2017
Ultrasensitive catalytic-adsorptive stripping voltammetric determination of molybdenum using a Mo(VI)-chloranilic acid-chlorate system / Jerzy ZARĘBSKI, Andrzej BOBROWSKI, Agnieszka KRÓLICKA, Rafał Bobrowski, Katarzyna Kwaśniewska // Electrochimica Acta : Journal of the International Society of Electrochemistry ; ISSN 0013-4686. — 2016 — vol. 208, s. 267–272. — Bibliogr. s. 271–272, Abstr. — Publikacja dostępna online od: 2016-05-07
artykuł
#72753Data dodania: 3.4.2013
Sensitive voltammetric determination of titanium (IV) in catalytic adsorptive mandelic acid-chlorate (V) system on renewable silver amalgam film electrode / Robert PIECH // Electroanalysis : an International Journal Devoted to Fundamental and Practical Aspects of Electroanalysis ; ISSN 1040-0397. — 2013 — vol. 25 no. 3 spec. iss.: Bioelectrochemistry and Electroanalytical Chemistry in France, s. 716–722. — Bibliogr. s. 721–722, Abstr.