Szczegóły publikacji
Opis bibliograficzny
A numerical evaluation of multi-tine electrode geometry and monopolar and bipolar operating modes on the efficacy of radiofrequency ablation in a hepatic tumor model / Martyna Gołębiowska, Arkadiusz Miaskowski, Piotr GAS // Applied Sciences (Basel) [Dokument elektroniczny]. — Czasopismo elektroniczne ; ISSN 2076-3417 . — 2026 — vol. 16 iss. 12 art. no. 5974, s. 1–21. — Wymagania systemowe: Adobe Reader. — Bibliogr. s. 19–21, Abstr. — Publikacja dostępna online od: 2026-06-12
Autorzy (3)
- Gołębiowska Martyna
- Miaskowski Arkadiusz
- AGHGas Piotr
Słowa kluczowe
Dane bibliometryczne
| ID BaDAP | 168525 |
|---|---|
| Data dodania do BaDAP | 2026-06-29 |
| Tekst źródłowy | URL |
| DOI | 10.3390/app16125974 |
| Rok publikacji | 2026 |
| Typ publikacji | artykuł w czasopiśmie |
| Otwarty dostęp | |
| Creative Commons | |
| Czasopismo/seria | Applied Sciences (Basel) |
Abstract
This study presents a comprehensive computational evaluation of radiofrequency (RF) ablation efficacy and the spatial formation of thermal ablation zones within a 3D model of a liver tumor. By systematically comparing these configurations, the study aims to elucidate the physical mechanisms governing electromagnetic (EM) energy dissipation in hepatic tissue and to provide clear engineering guidelines for optimizing RF applicator selection and treatment planning in clinical practice. To reliably simulate the biophysical phenomena of the RF ablation procedure, a coupled electro-thermal model based on the finite element method and the Pennes bioheat equation was implemented. The research investigates six distinct applicator variants: conventional needle-type applicators and advanced expandable umbrella-type RF applicators equipped with four- and eight-tine electrodes, each evaluated in both monopolar and bipolar configurations. Numerical simulations were conducted for a standard 10 min ablation procedure at varying applied voltages to assess the specific absorption rate (SAR) distribution, transient heating dynamics, and the exact volumes of the resulting coagulation necrosis which were quantified using rigorous isotherms and the cumulative equivalent minutes at 43 °C (CEM43) thermal dose index. Volumetric analysis of the ablation zones revealed that bipolar multi-tine electrodes induce highly localized heat concentration. Conversely, monopolar multi-tine setups strongly disperse EM energy. The results demonstrated that, for conventional needle applicators, the monopolar configuration generated significantly larger necrosis zones than the bipolar operating mode. The RF applicator geometry and its operating mode directly dictate the spatial extent of liver tissue necrosis. Moreover, advanced numerical treatment planning is essential for optimizing SAR and CEM43 distributions and ensuring safe and complete hepatocellular carcinoma eradication.