Influence of the radiofrequency applicators arrangement on the sizes of ablative zones inside hepatic tumor / Piotr GAS, Arkadiusz Miaskowski // Archives of Electrical Engineering ; ISSN 1427-4221. — Tytuł poprz.: Archiwum Elektrotechniki ; ISSN: 0004-0746. — 2024 — vol. 73 no. 3, s. 557-571. — Bibliogr. s. 568–571, Abstr. — Publikacja dostępna online od: 2024-09-24

Autorzy (2)

Słowa kluczowe

computational modellingheating techniquespercutaneous thermal ablationablation zoneshepatocellular carcinomafinite element methodRF electrodes

Dane bibliometryczne

ID BaDAP155527
Data dodania do BaDAP2024-09-25
Tekst źródłowyURL
DOI10.24425/aee.2024.150883
Rok publikacji2024
Typ publikacjiartykuł w czasopiśmie
Otwarty dostęptak
Creative Commons
Czasopismo/seriaArchives of Electrical Engineering

Abstract

Radiofrequency (RF) ablation is a popular therapeutic technique for heating solid tumors that are medically unsuitable for resection or other treatments. Thermal ablation applicators create high-frequency electromagnetic fields (EMFs) within the tumor site, which causes heating, coagulation, and ultimately death of the cancer cells. The aim of this study is the numerical analysis of the temperature distributions, ablation zones, and specific absorption rates (SAR) during RF ablation in relation to an ellipsoidal shaped tumor placed in the model of liver tissue. The source of heat is a three-element system of RF needle applicators operating at a frequency 100 kHz, with a given electrode potential, inserted into the tumor. In order to obtain an appropriate temperature distribution in the target area, the Laplace equation coupled with the Pennes equation were solved using the finite element method (FEM). The arrangement effect of three needle-type applicators on the resultant thermal profiles and the volumes of ablation zones were analyzed and compared. In addition, the ablation zones for various angles of the RF applicator placed in the center of the tumor were analyzed. The paper shows that in order to control temperature distribution and ablation zones the proposed system of RF applicators and the arrangement of electrodes can be successfully applied in hepatocellular carcinoma treatment.

Publikacje, które mogą Cię zainteresować

artykuł
#124116Data dodania: 4.10.2019
Influence of multi-tine electrode configuration in realistic hepatic RF ablative heating / Piotr GAS, Joanna Wyszkowska // Archives of Electrical Engineering ; ISSN 1427-4221. — Tytuł poprz.: Archiwum Elektrotechniki ; ISSN: 0004-0746. — 2019 — vol. 68 no. 3, s. 521–533. — Bibliogr. s. 531–533, Abstr.
fragment książki
#115662Data dodania: 11.9.2018
Evaluation of thermal damage of hepatic tissue during thermotherapy based on the Arrhenius model / Piotr GAS, Eugeniusz KURGAN // W: PAEE 2018 [Dokument elektroniczny] : Progress in Applied Electrical Engineering : Kościelisko (Zakopane), June 18–22, 2018. — Wersja do Windows. — Dane tekstowe. — [Piscataway] : IEEE, cop. 2018. — e-ISBN: 978-1-5386-6091-1. — S. [1–4]. — Wymagania systemowe: Adobe Reader. — Bibliogr. s. [4], Abstr.