Application assessment of electrical cables during smoldering and flaming combustion / Rafał POROWSKI, Robert Kowalik, Piotr Ramiączek, Paulina Bąk-Patyna, Paweł Stępień, Maria Zielecka, Tomasz Popielarczyk, Agata Ludynia, Angelika Chyb, Jarosław Gawdzik // Applied Sciences (Basel) [Dokument elektroniczny]. — Czasopismo elektroniczne ; ISSN 2076-3417. — 2023 — vol. 13 iss. 6 art. no. 3766, s. 1–23. — Wymagania systemowe: Adobe Reader. — Bibliogr. s. 21–23, Abstr. — Publikacja dostępna online od: 2023-03-15

Autorzy (10)

  • AGHPorowski Rafał
  • Kowalik Robert
  • Ramiączek Piotr
  • Bąk-Patyna Paulina
  • Stepień Paweł
  • Zielecka Maria
  • Popielarczyk Tomasz
  • Ludynia Agata
  • Chyb Angelika
  • Gawdzik Jarosław

Słowa kluczowe

combustion productssmoldering combustiontoxicityelectrical cableflaming combustion

Dane bibliometryczne

ID BaDAP145871
Data dodania do BaDAP2023-03-20
Tekst źródłowyURL
DOI10.3390/app13063766
Rok publikacji2023
Typ publikacjiartykuł w czasopiśmie
Otwarty dostęptak
Creative Commons
Czasopismo/seriaApplied Sciences (Basel)

Abstract

Electrical cables are a potential source of ignition and fire hazards in various types of buildings and industrial installations, as well as in all modes of transportation, including aircraft. Fires in buildings pose the greatest threat to human life and health. The composition of thermal degradation products depends mainly on the type of combustible materials and the type of combustion process—flaming or smoldering. The purpose of this paper was to determine, based on experimental studies, the effects of flaming and smoldering combustion on the response times of fire smoke detectors. In addition, the concentrations of fire gases formed in the process of duct combustion, including CO, SO2, NO2, NO, HCN, HCl, HBr and HF, were measured using an FTIR spectrometer. The results presented confirm the significant effect of the way the cable samples burned on detector tripping time. The highest concentration of smoke (Y) in the test chamber was obtained during flame combustion. It was further found that the characteristics of the cable insulation material used, such as the type of PVC, had a significant effect on the toxicity of the emitted gases. The largest amounts of toxic gases were emitted during the smoldering combustion of a cable with a plasticized PVC sheath.

Publikacje, które mogą Cię zainteresować

artykuł
#131240Data dodania: 2.12.2020
Chemistry and microbiology of urban roof runoff in Kraków, Poland with ecological and health risk implications / Magdalena STRZEBOŃSKA, Agnieszka GRUSZECKA-KOSOWSKA, Anna KOSTKA // Applied Sciences (Basel) [Dokument elektroniczny]. — Czasopismo elektroniczne ; ISSN 2076-3417. — 2020 — vol. 10 iss. 23 art. no. 8554, s. 1–20. — Wymagania systemowe: Adobe Reader. — Bibliogr. s. 15–20, Abstr. — Publikacja dostępna online od: 2020-11-29
artykuł
#122209Data dodania: 1.7.2019
A new approach to border irregularity assessment with application in skin pathology / Paweł KŁECZEK, Grzegorz Dyduch, Agnieszka Graczyk-Jarzynka, Joanna JAWOREK-KORJAKOWSKA // Applied Sciences (Basel) [Dokument elektroniczny]. — Czasopismo elektroniczne ; ISSN 2076-3417. — 2019 — vol. 9 iss. 10 art. no. 2022, s. 1–24. — Wymagania systemowe: Adobe Reader. — Bibliogr. s. 22–24, Abstr. — Publikacja dostępna online od: 2019-05-16