Szczegóły publikacji

Opis bibliograficzny

Detection of methanol contamination in ethyl alcohol employing a purpose-designed high-sensitivity microwave sensor / Ilona PIEKARZ, Krzysztof WINCZA, Sławomir GRUSZCZYŃSKI, Jakub SOROCKI // Measurement ; ISSN 0263-2241. — 2021 — vol. 174 art. no. 108993, s. 1–14. — Bibliogr. s. 14, Abstr. — Publikacja dostępna online od: 2021-01-17

Autorzy (4)

Słowa kluczowe

two wire sensortransmission line methodmethanol sensormethanol detectionliquid properties monitoring

Dane bibliometryczne

ID BaDAP132723
Data dodania do BaDAP2021-02-24
Tekst źródłowyURL
DOI10.1016/j.measurement.2021.108993
Rok publikacji2021
Typ publikacjiartykuł w czasopiśmie
Otwarty dostęptak
Czasopismo/seriaMeasurement

Abstract

A novel method for detection of low methanol contamination in ethyl alcohol is introduced. The approach is centered around sensing the electrical permittivity of the solution at low microwave frequency range where the difference in permittivity between two liquids is very high. A high-sensitivity substrate-less coplanar strip sensor is employed featuring an application-specific design maximizing sensitivity. The open-ended one-port-differential sensor is immersed in a methanol-ethanol solution and its differential reflection coefficient is measured, out of which the concentration of methanol can be determined in real time. The sensor‘s design procedure is provided that relies on analysis of the predicted solution‘s permittivity. The theoretical study was validated by measurements of a solutions with gradually increasing methanol concentration. The obtained results show the possibility to detect methanol content in ethyl alcohol being as low as 0.02% and prove the usefulness of the presented approach for, among others, neutral spirit quality control. © 2021 Elsevier Ltd.

Publikacje, które mogą Cię zainteresować

artykuł
#117085Data dodania: 22.10.2018
Liquids permittivity measurement using two-wire transmission line sensor / Ilona PIEKARZ, Jakub SOROCKI, Krzysztof WINCZA, Sławomir GRUSZCZYŃSKI // IEEE Sensors Journal ; ISSN 1530-437X. — 2018 — vol. 18 no. 18, s. 7458–7466. — Bibliogr. s. 7465–7466, Abstr.
artykuł
#146479Data dodania: 10.5.2023
High sensitivity and selectivity microwave biosensor using biofunctionalized differential resonant array implemented in LTCC for Escherichia coli detection / Ilona PIEKARZ, Jakub SOROCKI, Sabina Górska, Heike Bartsch, Artur RYDOSZ, Robert SMOLARZ, Krzysztof WINCZA, Sławomir GRUSZCZYŃSKI // Measurement ; ISSN 0263-2241. — 2023 — vol. 208 art. no. 112473, s. 1–8. — Bibliogr. s. 8, Abstr. — Publikacja dostępna online od: 2023-01-11