Szczegóły publikacji

Opis bibliograficzny

Energy monitoring in a heating and cooling system in a building based on the example of the Turówka hotel / Marek BOROWSKI, Piotr Mazur, Sławosz KLESZCZ, Klaudia ZWOLIŃSKA // Energies [Dokument elektroniczny]. — Czasopismo elektroniczne ; ISSN 1996-1073. — 2020 — vol. 13 iss. 8 art. no. 1968, s. 1–20. — Bibliogr. s. 18–19, Abstr. — This article belongs to the Special Issue Advanced Buildings Thermal Monitoring. — Publikacja dostępna online od: 2020-04-16. — S. Kleszcz - pierwsza afiliacja: Frapol Sp. z o. o., Kraków

Autorzy (4)

Słowa kluczowe

energy efficiencyventilationsustainable buildingsnearly zero energy buildingsheating and cooling systemenergy monitoring

Dane bibliometryczne

ID BaDAP128656
Data dodania do BaDAP2020-05-25
Tekst źródłowyURL
DOI10.3390/en13081968
Rok publikacji2020
Typ publikacjiartykuł w czasopiśmie
Otwarty dostęptak
Creative Commons
Czasopismo/seriaEnergies

Abstract

The energy consumption of buildings is very important for both economic and environmental reasons. Newly built buildings are characterized by higher insulation and airtightness of the building envelope, and are additionally equipped with technologies that minimize energy consumption in order to meet legal requirements. In existing buildings, the modernization process should be properly planned, taking into account available technologies and implementation possibilities. Hotel buildings are characterized by a large variability of energy demand, both on a daily and a yearly basis. Monitoring systems, therefore, provide the necessary information needed for proper energy management in the building. This article presents an energy analysis of the Turówka hotel located in Wieliczka (southern Poland). The historical hotel facility is being modernized as part of the project to adapt the building to the requirements of a sustainable building. The modernization proposal includes a trigeneration system with a multifunctional reverse regenerator and control module using neural algorithms. The main purpose is to improve the energy efficiency of the building and adapt it to the requirements of low-energy buildings. The implementation of a monitoring system enables energy consumption to be reduced and improves the energy performance of the building, especially through using energy management systems and control modules. The proposed retrofit solution considers the high energy consumption, structure of the energy demand, and limits of retrofit intervention on façades.

Publikacje, które mogą Cię zainteresować

artykuł
#143394Data dodania: 16.11.2022
Hotel adapted to the requirements of an nZEB building—thermal energy performance and assessment of energy retrofit plan / Marek BOROWSKI // Energies [Dokument elektroniczny]. — Czasopismo elektroniczne ; ISSN  1996-1073 . — 2022 — vol. 15 iss. 17 art. no. 6332, s. 1-17. — Wymagania systemowe: Adobe Reader. — Bibliogr. s. 16-17, Abstr. — Publikacja dostępna online od: 2022-08-30
artykuł
#131071Data dodania: 24.11.2020
Prediction of cooling energy consumption using a neural network on the example of the hotel building / Marek BOROWSKI, Klaudia ZWOLIŃSKA // Proceedings (MDPI) [Dokument elektroniczny]. — Czasopismo elektroniczne ; ISSN 2504-3900. — 2020 — vol. 58 iss. 1, art. no. 21, s. 1-11. — Wymagania systemowe: Adobe Reader. — Bibliogr. s. 10-11, Abstr. — Publikacja dostępna online od: 2020-09-11. — First World Energies Forum : 14 September – 5 October 2020