LC-MS/MS method validation for determination of selected neonicotinoids in groundwater for the purpose of a column experiment / Damian PIETRZAK, Katarzyna WĄTOR, Dorota Pękała, Justyna Wójcik, Aneta Chochorek, Ewa KMIECIK, Jarosław KANIA // Journal of Environmental Science and Health. Part B, Pesticides, Food Contaminants, and Agricultural Wastes ; ISSN 0360-1234. — 2019 — vol. 54 no. 5, s. 424–431. — Bibliogr. s. 429–431, Abstr. — Publikacja dostępna online od: 2019-03-01

Autorzy (7)

Słowa kluczowe

validationLC-MS/MSfitness for purposeneonicotinoidsground watercolumn experiment

Dane bibliometryczne

ID BaDAP121517
Data dodania do BaDAP2019-05-24
Tekst źródłowyURL
DOI10.1080/03601234.2019.1574173
Rok publikacji2019
Typ publikacjiartykuł w czasopiśmie
Otwarty dostęptak
Czasopismo/seriaJournal of Environmental Science and Health, Part B, Pesticides, Food Contaminants, and Agricultural Wastes

Abstract

The work was carried out to develop and validate a method based on liquid chromatography tandem mass spectrometry (LC-MS/MS) for the simultaneous detection and quantification of five neonicotinoid insecticides: acetamiprid, clothianidin, imidacloprid, thiacloprid and thiamethoxam in groundwater samples for the purpose of a further column experiment. This experiment will be used to analyze breakthrough curves of neonicotinoids under a saturated water flow to set transport parameters, where the reliability of the results of chemical analysis plays an important role. The validation was performed in a concentration range from 0.09 µg L−1 to 100 µg L−1 using an Infinity 1290 (Agilent, USA) chromatograph coupled with a QTrap 5500 mass spectrometer (Sciex, Canada). The calibration curves were obtained on the basis of the results of six standard solution analyses. Linearity was not lower than 0.998. The limit of detection was set at the lowest concentration which can be determined with an acceptable accuracy and precision. All pesticides had recoveries in the range 85–109% with relative standard deviation values less than 8.1%. The estimated measurement uncertainty did not exceed 30%, so the LC-MS/MS method fits for the intended purpose.

Publikacje, które mogą Cię zainteresować

fragment książki
#115015Data dodania: 17.7.2018
LC-MS/MS method validation for determination of selected neonicotinoids in groundwater for the purpose of a column experiment / WĄTOR Katarzyna, PIETRZAK Damian, Pękała Dorota, Wójcik Justyna, Chochorek Aneta, KMIECIK Ewa, KANIA Jarosław // W: Ecological and environmental engineering : the first international scientific conference : 26–29 June 2018 Kraków, Poland : book of abstracts / eds. Krzysztof Jóźwiakowski, Agnieszka Listosz, Alina Kowalczyk-Juśko. — Lublin : Perfekta info, [2018]. — ISBN: 978-8363657-99-4. — S. 161. — Dostęp również online: https://coee.urk.edu.pl/zasoby/164/Book.pdf
fragment książki
#114338Data dodania: 7.6.2018
Accuracy of LC-MS/MS method for the determination of concentration of pesticides from the first Watch List in groundwater / D. PIETRZAK, K. WĄTOR, D. Pękała, J. Wójcik, A. Chochorek, E. KMIECIK // W: New Technologies in Water Sector [Dokument elektroniczny] : 10th Eastern European Young Water Professionals Conference : 7-12 May 2018, Zagreb, Croatia : conference proceedings / ed. Maryna Feierabend, [et al.]. — Wersja do Windows. — Dane tekstowe. — Zagreb : [s. n.], 2018. — S. 135–141. — Wymagania systemowe: Adobe Reader. — Tryb dostępu: http://iwa-ywp.eu/wp-content/uploads/2018/05/Conference-Proce... [2018-06-06]. — Bibliogr. s. 140–141, Abstr.