Comparison of MCP-Ns and MCP-N detectors usefulness for beta rays detection / Katarzyna MATUSIAK, Aneta Patora, Aleksandra JUNG // Radiation Measurements ; ISSN 1350-4487. — 2017 — vol. 102, s. 10–15. — Bibliogr. s. 15, Abstr. — Publikacja dostępna online od: 2017-06-02

Autorzy (3)

Słowa kluczowe

thermoluminescent detectorsMCP-Nsbeta radiation dosimetry

Dane bibliometryczne

ID BaDAP106684
Data dodania do BaDAP2017-07-13
Tekst źródłowyURL
DOI10.1016/j.radmeas.2017.05.009
Rok publikacji2017
Typ publikacjiartykuł w czasopiśmie
Otwarty dostęptak
Czasopismo/seriaRadiation Measurements

Abstract

In this study thin LiF:Mg,Cu,P dosimeters (trade name MCP-Ns) designed for measurements in beta radiation fields were tested in comparison with classical LiF:Mg,Cu,P ones (trade name MCP-N). The readout stability as well as TLD response in low (∼kBq) and high (∼MBq) radioactivity fields (beta and beta-gamma) were verified. The stability of MCP-Ns decreased during first 10 complete measuring cycles and then detectors appeared to be stable. Unfortunately, around 60th cycle the stability was lost. In the MCP-N group the stabilization was observed from 20th cycle but it was maintained in further measuring cycles. The MCP-Ns response in low radioactivity fields (∼kBq) was difficult to verify (dose values oscillated around the “zero dose reading”), reliable results were observed for high radioactivity fields (∼MBq). The dose measured by MCP-Ns was ten times higher in beta fields and around five times higher in mixed beta-gamma fields in comparison to the MCP-N. MCP-Ns seems to be adequate and more sensitive to measure beta dose or mixed beta-gamma dose, however the uncertainty of a single measurement has to be under more careful control compared to MCP-N which have higher repeatability and stability.

Publikacje, które mogą Cię zainteresować

artykuł
#132525Data dodania: 17.2.2021
The impact of accidental immersion in selected liquids on the sensitivity and repeatability of MCP-N thermoluminescent detectors / A. JUNG, K. MATUSIAK // Radiation Measurements ; ISSN 1350-4487. — 2021 — vol. 141 art. no. 106525, s. 1–6. — Bibliogr. s. 6, Abstr. — Publikacja dostępna online od: 2021-01-24
artykuł
#169671Data dodania: 28.9.2026
Impact of regeneration on the dosimetric properties of LiF:Mg,Cu,P (MCP-N) detectors / Patrycja Gordon, Katarzyna MATUSIAK, Mariusz Kłosowski, Aleksandra JUNG // Sensors [Dokument elektroniczny]. — Czasopismo elektroniczne ; ISSN  1424-8220 . — 2026 — vol. 26 iss. 16 art. no. 5176, s. 1–22. — Wymagania systemowe: Adobe Reader. — Bibliogr. s. 20–22, Abstr. — Publikacja dostępna online od: 2026-08-15