Measuring compositions in organic depth profiling: results from a VAMAS interlaboratory study / Alexander G. Shard, [et al.], Andrzej BERNASIK, [et al.], Mateusz M. MARZEC, [et al.] // Journal of Physical Chemistry. B ; ISSN 1520-6106. — 2015 — vol. 119 iss. 33, s. 10784–10797. — Bibliogr. s. 10796–10797, Abstr.


Autorzy (32)


Dane bibliometryczne

ID BaDAP95426
Data dodania do BaDAP2016-02-10
DOI10.1021/acs.jpcb.5b05625
Rok publikacji2015
Typ publikacjiartykuł w czasopiśmie
Otwarty dostęptak
Czasopismo/seriaJournal of Physical Chemistry, B

Abstract

We report the results of a VAMAS (Versailles Project on Advanced Materials and Standards) interlaboratory study on the measurement of composition in organic depth profiling. Layered samples with known binary compositions of Irganox 1010 and either Irganox 1098 or Fmoc-pentafluoro-l-phenylalanine in each layer were manufactured in a single batch and distributed to more than 20 participating laboratories. The samples were analyzed using argon cluster ion sputtering and either X-ray photoelectron spectroscopy (XPS) or time-of-flight secondary ion mass spectrometry (ToF-SIMS) to generate depth profiles. Participants were asked to estimate the volume fractions in two of the layers and were provided with the compositions of all other layers. Participants using XPS provided volume fractions within 0.03 of the nominal values. Participants using ToF-SIMS either made no attempt, or used various methods that gave results ranging in error from 0.02 to over 0.10 in volume fraction, the latter representing a 50% relative error for a nominal volume fraction of 0.2. Error was predominantly caused by inadequacy in the ability to compensate for primary ion intensity variations and the matrix effect in SIMS. Matrix effects in these materials appear to be more pronounced as the number of atoms in both the primary analytical ion and the secondary ion increase. Using the participants’ data we show that organic SIMS matrix effects can be measured and are remarkably consistent between instruments. We provide recommendations for identifying and compensating for matrix effects. Finally, we demonstrate, using a simple normalization method, that virtually all ToF-SIMS participants could have obtained estimates of volume fraction that were at least as accurate and consistent as XPS.

Publikacje, które mogą Cię zainteresować

artykuł
XPS depth profiling of organic photodetectors with the gas cluster ion beam / Jakub HABERKO, Mateusz M. MARZEC, Andrzej BERNASIK, Wojciech ŁUŻNY, Pierre Lienhard, Alexandre Pereira, Jérôme Faure-Vincent, David Djurado, Amélie Revaux // Journal of Vacuum Science & Technology. B, Microelectronics and Nanometer Structures ; ISSN 1071-1023. — 2016 — vol. 34 iss. 3, s. 03H119-1–03H119-5. — Publikacja dostępna online od: 2016-03-04. — A. Bernasik – dod. afiliacja: ACMiN
artykuł
Excitation energy trapping and dissipation by $Ni$-substituted bacteriochlorophyll $a$ in reconstituted LH1 complexes from Rhodspirillum rubrum / Petar H. Lambrev, [et al.], Joanna FIEDOR, [et al.] // Journal of Physical Chemistry. B ; ISSN 1520-6106. — 2013 — vol. 117 iss. 38 spec. iss., s. 11260–11271. — Bibliogr. s. 11269–11271, Abstr.