Szczegóły publikacji

Opis bibliograficzny

The renewable bismuth bulk annular band working electrode: fabrication and application in the adsorptive stripping voltammetric determination of nickel(II) and cobalt(II) / Bogusław BAŚ, Krystian WĘGIEL, Katarzyna JEDLIŃSKA // Analytica Chimica Acta ; ISSN 0003-2670. — 2015 — vol. 881, s. 44–53. — Bibliogr. s. 52–53, Abstr. — Publikacja dostępna online od: 2015-05-07

Autorzy (3)

Słowa kluczowe

nickelwater analysisstripping voltammetrymercury-free electroanalysisbismuth bulk electrodecobalt

Dane bibliometryczne

ID BaDAP89799
Data dodania do BaDAP2015-06-18
Tekst źródłowyURL
DOI10.1016/j.aca.2015.05.005
Rok publikacji2015
Typ publikacjiartykuł w czasopiśmie
Otwarty dostęptak
Czasopismo/seriaAnalytica Chimica Acta

Abstract

The paper presents the first report on fabrication and application of a user friendly and mercury free electrochemical sensor, with the renewable bismuth bulk annular band working electrode (RBiABE), in stripping voltammetry (SV). The sensor body is partly filled with the internal electrolyte solution, in which the RBiABE is cleaned and activated before each measurement. Time of the RBiABE contact with the sample solution is precisely controlled. The usefulness of this sensor was tested by Ni(II) and Co(II) traces determination by means of differential pulse adsorptive stripping voltammetry (DP AdSV), after complexation with dimethylglyoxime (DMG) in ammonia buffer (pH 8.2). The experimental variables (composition of the supporting electrolyte, pre-concentration potential and time, potential of the RBiABE activation, and DP parameters), as well as possible interferences, were investigated. The linear calibration graphs for Ni(II) and Co(II), determined individually and together, in the range from 1×10-8 to 70×10-8molL-1 and from 1×10-9 to 70×10-9molL-1 respectively, were obtained. The calculated limit of detection (LOD), for 30s of the accumulation time, was 3×10-9molL-1 for Ni(II) in case of a single element's analysis, whereas the LOD was 5×10-9molL-1 for Ni(II) and 3×10-10molL-1 for Co(II), when both metal ions were measured together. The repeatability of the Ni(II) and Co(II) adsorptive stripping voltammetric signals obtained at the RBiABE were equal to 5.4% and 2.5%, respectively (n=5). Finally, the proposed method was validated by determining Ni(II) and Co(II) in the certified reference waters (SPS-SW1 and SPS-SW2) with satisfactory results. © 2015.

Publikacje, które mogą Cię zainteresować

fragment książki
#89074Data dodania: 15.5.2015
Construction and application of bismuth bulk electrode for adsorptive stripping determination of cobalt(II) / Krystian WĘGIEL, Bogusław BAŚ // W: EYEC monograph : 4th European Young Engineers Conference : April 27–29th 2015, Warsaw / ed. Michał Wojasiński, Bartosz Nowak ; Scientific Club of Chemical and Process Engineering. Faculty of Chemical and Process Engineering. Warsaw University of Technology. — Warsaw : University of Technology. Faculty of Chemical and Process Engineering, cop. 2015. — Na okł. dod.: 100 lecie odnowienia tradycji Politechniki Warszawskiej. — ISBN: 978-83-936575-1-3. — S. 443
artykuł
#91923Data dodania: 24.9.2015
New voltammetric sensor based on the renewable bismuth bulk annular band electrode and its application for the determination of palladium(II) / Bogusław BAŚ, Krystian WĘGIEL, Katarzyna JEDLIŃSKA // Electrochimica Acta : Journal of the International Society of Electrochemistry ; ISSN 0013-4686. — 2015 — vol. 178, s. 665–672. — Bibliogr. s. 672, Abstr.