The use of a custom mode electron capture detector to determine mixing ratios of environmental tracers: sulfur hexafluoride, chlorotrifluoromethane and bromotrifluoromethane / J. ROSIEK, J. BARTYZEL, K. RÓŻAŃSKI, I. Śliwka // Journal of Chromatography ; ISSN 0021-9673. A. — 2013 — vol. 1282, s. 194–198. — Bibliogr. s. 198, Abstr.


Autorzy (4)


Słowa kluczowe

CF3BrCF3ClECDresonance detection mode

Dane bibliometryczne

ID BaDAP79401
Data dodania do BaDAP2014-01-29
Tekst źródłowyURL
DOI10.1016/j.chroma.2013.01.088
Rok publikacji2013
Typ publikacjiartykuł w czasopiśmie
Otwarty dostęptak
Czasopismo/seriaJournal of Chromatography, A

Abstract

Atmospheric concentrations of anthropogenic trace gases, such as sulfur hexafluoride, SF6, chlorotrifluoromethane, CF3Cl, and bromotrifluoromethane, CF3Br, are increasing. Their long lifetimes and limited chemical reactivity make them attractive environmental tracers for hydrology and oceanography. While ambient SF6 concentrations can be readily measured using GC-ECD, the simultaneous analysis of CF3Cl and CF3Br is hampered due to their low ECD sensitivity. The response of a commercial ECD for those gases was enhanced using the resonance detection mode which is based on shifting the mean energy of electrons in the ECD detector towards the region where the electron-capture reaction reveals a distinct maximum. A custom electronic system enabled operation of a commercial ECD in the resonance detection mode. An approximately 50-fold amplification of the ECD signal was obtained for CF3Cl by application of high-frequency electric field (amplitude of 50V and frequency of 40 MHz). For CF3Br, a 3.5-fold increase of the ECD ignal was obtained, with a lower HF field (20-30V). In the case of SF6 the application of the HF field reduces the magnitude of ECD signal by a factor of 40. The electron-capture coefficients for SF6, CF3Cl and CF3Br were determined from 453 to 633 K in the standard and the resonance modes. The electron-capture coefficients for CF(3)Cland CF3Br increase with increasing temperature for both modes, while that for SF6 decreases slightly with increasing temperature. The application of the resonance detection mode to a commercial ECD provides an attractive and cost-effective alternative to GCMS for high-quality quantitative analyses of CF3Cl and CF3Br as environmental tracers. (C) 2013 Elsevier B.V. All rights reserved.

Publikacje, które mogą Cię zainteresować

artykuł
Application of a pulse-discharge helium detector to the determination of neon in air and water / J. LASA, P. Mochalski, E. Łokas, L. KĘDZIOR // Journal of Chromatography ; ISSN 0021-9673. A. — 2002 — vol. 968 iss. 1–2 art. no. PII S0021-9673(02)00844-0, s. 263–267. — Bibliogr. s. 266–267, Abstr.