Szczegóły publikacji

Opis bibliograficzny

Catalytic adsorptive stripping voltammetry of Co(II)-dioxime-bromate systems at renewable amalgam film electrode / A. BOBROWSKI, A. KRÓLICKA, M. PUTEK, J. ZARĘBSKI, N. Čelebić, V. Guzsvány // Electrochimica Acta : Journal of the International Society of Electrochemistry ; ISSN 0013-4686. — 2013 — vol. 107, s. 93–102. — Bibliogr. s. 102, Abstr.

Autorzy (6)

Słowa kluczowe

cobaltsilver amalgam film electrodedimethylglyoximecatalytic adsorptive stripping voltammetrybromatenickel

Dane bibliometryczne

ID BaDAP75116
Data dodania do BaDAP2013-08-13
Tekst źródłowyURL
DOI10.1016/j.electacta.2013.05.132
Rok publikacji2013
Typ publikacjiartykuł w czasopiśmie
Otwarty dostęptak
Czasopismo/seriaElectrochimica Acta

Abstract

The properties, sensitivity and selectivity of several catalytic adsorptive systems consisting of Co(II)-dioximate complexes (dimethylglyoxime (DMG), nioxime) and the oxidation agents (bromate or nitrite) were compared in conditions of adsorptive stripping voltammetry at the hanging mercury drop or amalgam film (Hg(Ag)FE) electrodes. For this purpose the catalytic behaviour of the catalytic systems Co(II)-nitrite and Co(II)-bromate in the absence of dioximes was also investigated. It was demonstrated that the Co(II)-(NH3) x complex induces the catalytic reduction of BrO3- ions in the ammonia buffer solution. The electrode mechanism of the reduction of the most sensitive system, i.e. Co(II)-DMG-BrO3-, was elucidated by means of cyclic voltammetry and using criteria established for square wave voltammetry. It was assumed that in the Co(II)-DMG-BrO3-system the intermediate product-the composite complex of Co(II) with DMG and BrO3 - - takes part in the cyclic catalytic reduction of BrO3-ions. Combining adsorptive stripping accumulation with the catalytic enhancement of the analytical signal of Co(II)-DMG by BrO3 - ensures extremely high sensitivity of Co determination. After 60s of accumulation at -0.7V in the supporting electrolyte containing 6.5 × 10-5M DMG, 0.2 M BrO3- and 0.1 M ammonia buffer, cobalt may be determined in the concentration range of 5 × 10-10-1 × 10 -7MCo(II) by means of SW-CAdSV at the Hg(Ag)FE. The limit of detection was 1 × 10-10M Co. The proposed method of cobalt determination was successfully applied and validated by studying the certified reference material TMRAIN-95 (water sample). The elaborated method ensures very sensitive determination of Co(II) as well as simultaneous estimation of Co(II) and Ni(II) in the presence of a 4000-fold excess of Zn(II). © 2013 Elsevier Ltd. All rights reserved.

Publikacje, które mogą Cię zainteresować

artykuł
#77534Data dodania: 8.11.2013
Catalytic adsorptive stripping chronopotentiometry of $Co(II)-DMG-bromate$ system at an in situ plated lead film electrode / Andrzej BOBROWSKI, Agnieszka KRÓLICKA, Maria PUTEK, Jerzy ZARĘBSKI, Nikolas Antonatos, Anastasios Economou // Electroanalysis : an International Journal Devoted to Fundamental and Practical Aspects of Electroanalysis ; ISSN 1040-0397. — 2013 — vol. 25 no. 10, s. 2298–2304. — Bibliogr. s. 2304, Abstr.
fragment książki
#85068Data dodania: 4.11.2014
Catalytic adsorptive stripping chronopotentiometric determination of Co(II) at lead film electrode / Andrzej BOBROWSKI, Agnieszka KRÓLICKA, Maria PUTEK, Jerzy ZARĘBSKI, Nikolas Antonatos, Anastasios Economou // W: AACD 2014 [Dokument elektroniczny] : 9th Aegean Analytical Chemistry Days : 29 September – 3 October 2014, Chios, Greece : book of abstracts. — Wersja do Windows. — Dane tekstowe. — [Greece : s. n.], [2014]. — Dysk Flash. — S. [1], P1-17. — Wymagania systemowe: Adobe Reader. — Bibliogr. s. [1]