Szczegóły publikacji

Opis bibliograficzny

Accuracy of the element geometry mapping using non-invasive computer tomography method / Mirosław Grzelka, Lidia Marciniak, Bartosz Gapiński, Grzegorz Budzik, Andrzej Trafarski, Joanna AUGUSTYN-PIENIĄŻEK, Mariusz Gaca // Journal of Automation, Mobile Robotics & Intelligent Systems : JAMRIS ; ISSN 1897-8649. — 2012 — vol. 6 no. 3, s. 23–26. — Bibliogr. s. 25–26, Abstr.

Autorzy (7)

Słowa kluczowe

accuracy of workpiece mappingreverse engineeringoptical coordinate measuring techniquecomputer tomography

Dane bibliometryczne

ID BaDAP66569
Data dodania do BaDAP2012-06-22
Tekst źródłowyURL
Rok publikacji2012
Typ publikacjiartykuł w czasopiśmie
Otwarty dostęptak
Creative Commons
Czasopismo/seriaJournal of Automation, Mobile Robotics and Intelligent Systems

Abstract

Non-invasive method of the measurement and identification of shape and geometrical characteristics of measured detail based on the computer tomograph is widely applied in medicine with high efficiency. The paper is aimed at presenting the metrological analysis of the accuracy of shape reproduction. The examined shape was described due to the tomography and compared to the results of coordinate measurement. The comparative accuracy analysis of the tomography was performed for the typical details, as well as for the masters made with high accuracy. Using the results of the analysis, the respective models of measured details were created and used as a nominal in the further investigations. The results of the measurement with tomography were compared with the results achieved from the measurement by means of typical coordinate measuring machines and by means of 3D measurement optical scanner. Analysis of the gained values of the form deviations and important geometrical characteristics enabled to perform complex analysis of the shape reproduction of the examined detail with the method of computer tomography. The main purpose of the performed researches was the determination of the reproduction accuracy of surface measured with non-invasive computer tomography method. The investigations and analysis have been performed with the following equipment: computer tomograph, 3D printer and coordinate optical scanner supported with specialized software for advanced CAD data analysis.

Publikacje, które mogą Cię zainteresować

fragment książki
#62263Data dodania: 18.11.2011
Accuracy of the element geometry mapping using non-invasive computer tomography method / Mirosław Grzelka, Lidia Marciniak, Bartosz Gapiński, Grzegorz Budzik, Andrzej Trafarski, Joanna AUGUSTYN-PIENIĄŻEK, Mariusz Gaca // W: Metrologia w Technikach Wytwarzania (MwTW) : XIV krajowa i V międzynarodowa konferencja naukowo-techniczna = Metrology in Production Engineering : XIV national and international scientific and technical conference : Warszawa–Pułtusk, 12–14.09.2011 / Politechnika Warszawska. Wydział Mechatroniki. Instytut Metrologii i Inżynierii Biomedycznej. — [Warszawa : PW], [2011]. — S. 98–103. — Bibliogr. s. 102–103, Abstr.
artykuł
#94780Data dodania: 22.1.2016
The application of spherical standards for the evaluation of the accuracy of mapping shape in computed tomography / Andrzej Ryniewicz, Ksenia Ostrowska, Wojciech Ryniewicz, Jerzy Sładek, Łukasz BOJKO, Marcin Krawczyk // Bio-Algorithms and Med-Systems / Jagiellonian University. Medical College ; ISSN 1895-9091. — 2015 — vol. 11 iss. 4, s. 231–236. — Bibliogr. s. 236, Abstr. — Publikacja dostępna online od: 2015-11-20