Szczegóły publikacji

Opis bibliograficzny

Total reflection X-ray fluorescence attachment module modified for analysis in vacuum / P. Wobrauschek, C. Streli, P. Kregsamer, F. Meirer, C. Jokubonis, A. Markowicz, D. WĘGRZYNEK, E. Chinea-Cano // Spectrochimica Acta. Part B, Atomic spectroscopy ; ISSN 0584-8547. — 2008 — vol. 63 iss. 12, s. 1404–1407. — Bibliogr. s. 1407, Abstr. — A. Markowicz - brak afiliacji AGH. D. Węgrzynek - dod. afiliacja: International Atomic Energy Agency, Vienna. — 12th international conference on Total reflection X-ray fluorescence analysis and related methods : June 18–22, 2007 : Trento, Italy

Autorzy (8)

  • Wobrauschek P.
  • Streli C.
  • Kregsamer Peter
  • Meirer Florian
  • Jokubonis Christoph
  • Markowicz A.
  • AGHWęgrzynek Dariusz
  • Chinea-Cano Ernesto

Słowa kluczowe

trace element analysisTXRFvacuum tube collectors

Dane bibliometryczne

ID BaDAP45336
Data dodania do BaDAP2009-05-22
Tekst źródłowyURL
DOI10.1016/j.sab.2008.10.020
Rok publikacji2008
Typ publikacjireferat w czasopiśmie
Otwarty dostęptak
Czasopismo/seriaSpectrochimica Acta, Part B, Atomic Spectroscopy

Abstract

Based on the design of the low cost Total Reflection X-Ray Fluorescence attachment module available since 1986 from Atominstitut (WOBRAUSCHEK-module) which can be attached to existing X-ray equipment, a new version was developed which allows the analysis of samples in vacuum. This design was in particular possible as the Peltier cooled light weight Silicon Drift Detector is following all adjustment procedures for total reflection as angle rotation and linear motion. The detector is mounted through a vacuum feed and O-ring tightening to the small vacuum chamber. The standard 30 mm round quartz, Si-wafer or Plexiglas reflectors are used to carry the samples. The reflectors are placed on the reference plane with the dried sample down looking facing in about 0.5 mm distance the up looking detector window. The reflectors are resting on 3 steel balls defining precisely the reference plane for the adjustment procedure. As the rotation axis of the module is in the plane of the reflector surface, angle dependent experiments can be made to distinguish between film and particulate type contamination of samples. Operating with a Mo anode at 50 kV and 40 mA with a closely attached multilayer monochromator and using a 10 mm(2) KETEK silicon drift detector with 8 pm Be window, a sensitivity of 70 cps/ng for Rb was measured and detection limits of 2 pg were obtained. (C) 2008 Elsevier B.V. All rights reserved.

Publikacje, które mogą Cię zainteresować

artykuł
#31251Data dodania: 3.2.2007
Analysis of some chosen elements of cerebrospinal fluid and serum in amyotrophic lateral sclerosis patients by total reflection X-ray fluorescence / B. OSTACHOWICZ, M. LANKOSZ, B. Tomik, D. Adamek, P. Wobrauschek, C. Streli, P. Kregsamer // Spectrochimica Acta . Part B, Atomic spectroscopy ; ISSN  0584-8547. — 2006 — vol. 61 iss. 10–11, s. 1210–1213. — Bibliogr. s. 1213, Abstr. — Publikacja dostępna online od: 2006-10-12. — TXRF-2005 : 11th International Conference on Total Reflection X-ray Fluorescence Spectrometry and Related Methods : 18-22 September 2005, Budapest, Hungary
artykuł
#159128Data dodania: 9.5.2025
Optimisation of the drying method during sample preparation for total reflection X-ray fluorescence measurements using acid digested biological reference materials / Paula KASPRZYK, Paweł M. WRÓBEL, Wiktoria Tokarczyk, Magdalena SZCZERBOWSKA-BORUCHOWSKA // Spectrochimica Acta . Part B, Atomic spectroscopy ; ISSN  0584-8547. — 2025 — vol. 228 art. no. 107187, s. 1–6. — Bibliogr. s. 6, Abstr. — Publikacja dostępna online od: 2025-03-12