Dynamic heart phantom for the Quality Control of SPECT equipment / Katarzyna MATUSIAK, Marta WASILEWSKA-RADWAŃSKA, Artur Stępień // Physica Medica : European Journal of Medical Physics ; ISSN 1120-1797. — 2008 — vol. 24 iss. 2, s. 112–116. — Bibliogr. s. 116, Abstr. — Publikacja dostępna online od: 2008-03-10. — 1st European Conference on Medical Physics : September 20–22, 2007 : Pisa, Italy

Autorzy (3)

Słowa kluczowe

SPECTquality controldynamic heart phantom

Dane bibliometryczne

ID BaDAP40556
Data dodania do BaDAP2008-10-08
Tekst źródłowyURL
DOI10.1016/j.ejmp.2008.01.015
Rok publikacji2008
Typ publikacjireferat w czasopiśmie
Otwarty dostęptak
Czasopismo/seriaPhysica Medica

Abstract

A nuclear imaging of heart is a noninvasive procedure that reveals the cardiac structure and physiology enabling evaluation of cardiac function. According to the regulations published by the Polish Government and the Polish Ministry of Health, the nuclear medicine departments must follow the new legislation which has imposed quality assurance (QA) and quality control, (QC) of equipment and medical testing procedures as compulsory. The foremost reason to perform QC tests of medical. imaging equipment, using ionizing radiation, is to assure the provision of the best possible diagnostic service to the patient with the least radiological hazard. One of the most common ways of testing in nuclear medicine is using phantoms. The aim of this study was to design and perform a dynamic heart phantom. The heart phantom was designed according to directive of the ICRU Report 48. It consists of a pump, tubes, cardiac volume and a membrane simulating left ventricle. The pump compresses and decompresses membrane. The pumping frequency can be changed from 60 to 200 bpm. The phantom cardiac volume should be fitted with radiopharmaceutical. The elaborated dynamic heart phantom is used for QC of imaging system in nuclear medicine department. The QC measurements were performed with the phantom filled with 45-50 MBq of Tc-99m- solution and placed in water filled anthropomorphic torso phantom. The dynamic heart phantom can also be used to simulate all types of the myocardial infarctions and help to choose the best geometry of the measurement. (C) 2008 Published by Elsevier Ltd on behalf of Associazione Italiana di Fisica Medica.

Publikacje, które mogą Cię zainteresować

fragment książki
#35011Data dodania: 25.10.2007
Dynamic heart phantom for the Quality Control of SPECT equipment / K. MATUSIAK, M. WASILEWSKA-RADWAŃSKA, A. Stepien // W: Xth EFOMP congress – Pisa 2007 : first European conference on Medical Physics : physics in radiotherapy, diagnostic radiology, nuclear medicine ; medical imaging ; physiological measurements ; molecular imaging ; radioprotection ; education and training in medical physics : Castelvecchio Pascoli (LU), Italy, 20–22 September, 2007 : book of abstracts / Aifm Associazione Italiana di Fisica Medica [etc.]. — [Italy : Aifm], [2007]. — S. 20, P2-6. — Bibliogr. s. 20
artykuł
#165393Data dodania: 14.1.2026
A novel agar-based phantom for quality control of medical ultrasound devices / Katarzyna MATUSIAK, Weronika Banowska // Polish Journal of Medical Physics and Engineering ; ISSN  1425-4689 . — 2025 — vol. 31 iss. 4, s. 319-323. — Bibliogr. s. 323, Abstr.