Szczegóły publikacji

Opis bibliograficzny

Renewable copper and silver amalgam film electrodes of prolonged application for the determination of elemental sulfur using stripping voltammetry / Robert PIECH, Bogusław BAŚ, Ewa NIEWIARA, Władysław W. KUBIAK // Electroanalysis : an International Journal Devoted to Fundamental and Practical Aspects of Electroanalysis ; ISSN 1040-0397. — 2008 — vol. 20 no. 7, s. 809–815. — Bibliogr. s. 814–815, Abstr. — Publikacja dostępna online od: 2008-02-01

Autorzy (4)

Słowa kluczowe

trace analysismercury film electrodesamalgam electrodesstripping voltammetryelemental sulfur

Dane bibliometryczne

ID BaDAP38317
Data dodania do BaDAP2008-04-01
Tekst źródłowyURL
DOI10.1002/elan.200704106
Rok publikacji2008
Typ publikacjiartykuł w czasopiśmie
Otwarty dostęptak
Czasopismo/seriaElectroanalysis

Abstract

New, renewable copper (Hg(Cu)FE) and silver (Hg(Ag)FE) based amalgam film electrodes applied for the determination of elemental sulfur using differential pulse cathodic stripping voltammetry are presented. With surface areas adjustable from 1 to 12 mm(2), both electrodes are characterized by very good surface reproducibility (<= 2%) and long-term stability (a few thousand measurement cycles). The mechanical refreshing of the amalgam film takes about 1-2 seconds. The effects of various factors such as instrumental parameters and the supporting electrolyte composition were optimized. Interferences from sulfides are easily removed by the addition of acid, and bubbling with argon, for Hg(Ag)FE. In the case of Hg(Cu)FE, sulfides did not interfere. The calibration graph is linear within the studied range from 16 ng L-1 to 4.8 mu g L-1 for Hg(Cu)FE, and up to 6.4 mu g L-1 for Hg(Ag)FE (t(acc)=15 s). The correlation coefficients for the two electrodes were at least 0.997. The detection limits for a low concentration of S(0) and t(acc)=60 s are as low as 14 ng L-1 for Hg(Cu)FE and 4 ng L-1 for Hg(Ag)FE. The proposed method was successfully applied and validated by studying the recovery of S(0) from spiked river water.

Publikacje, które mogą Cię zainteresować

artykuł
#41804Data dodania: 27.11.2008
Determination of selenium traces on cyclic renewable mercury film silver electrode in presence of copper ions using cathodic stripping voltammetry / Robert PIECH // Electroanalysis : an International Journal Devoted to Fundamental and Practical Aspects of Electroanalysis ; ISSN  1040-0397 . — 2008 — vol. 20 no. 22, s. 2475–2481. — Bibliogr. s. 2481, Abstr. — Publikacja dostępna online od: 2008-10-22
artykuł
#35399Data dodania: 12.11.2007
The cyclic renewable mercury film silver based electrode for determination of uranium(VI) traces using adsorptive stripping voltammetry / Robert PIECH, Bogusław BAŚ, Władysław W. KUBIAK // Electroanalysis : an International Journal Devoted to Fundamental and Practical Aspects of Electroanalysis ; ISSN 1040-0397. — 2007 — vol. 19 no. 22, ekran 2342–-2350. — Tryb dostępu: http://www3.interscience.wiley.com/cgi-bin/fulltext/116320024... [2007-11-12]. — Bibliogr. ekran 2349–2350, Abstr.