Szczegóły publikacji

Opis bibliograficzny

RX64DTH – a fully integrated 64-channel ASIC for a digital X-ray imaging system with energy window selection / P. GRYBOŚ, A. E. Cabal Rodriguez, M. IDZIK, J. Lopez Gaitan, F. Prino, L. Ramello, K. ŚWIENTEK, P. WIĄCEK // IEEE Transactions on Nuclear Science ; ISSN 0018-9499. — 2005 — vol. 52 no. 4, s. 839–846. — Bibliogr. s. 846, Abstr. — Publikacja dostępna online od: 2005-08-15

Autorzy (8)

Słowa kluczowe

front-end electronicsdigital X-ray imagingASIC

Dane bibliometryczne

ID BaDAP34505
Data dodania do BaDAP2007-10-03
Tekst źródłowyURL
DOI10.1109/TNS.2005.852631
Rok publikacji2005
Typ publikacjiartykuł w czasopiśmie
Otwarty dostęptak
Czasopismo/seriaIEEE Transactions on Nuclear Science

Abstract

We report on the multichannel IC (RX64DTH) designed for position sensitive X-ray measurements with silicon strip detectors and dedicated to medical imaging applications. This integrated circuit has a binary readout architecture with a double threshold allowing on selection energy window for measured signals. The design was realized in a 0.8 mu m CMOS process. The core of the RX64DTH IC consists of 64 readout channels. The single channel is built with four basic blocks: charge sensitive preamplifier, shaper, two independent discriminators, and two independent 20-bit counters. Each readout channel counts pulses which are above the low discriminator threshold and counts pulses independently above the high discriminator threshold. The energy resolution in such architecture is limited by the noise of a single channel and by channel to channel threshold spread. We present the noise and matching performance of a 384-channel module built with a silicon strip detector and six RX64DTH ICs. In the 384-channel module an equivalent noise charge of about 200 el. rms is achieved for the shaper peaking time of 0.8 mu s and strip capacitance of 3 pF. The deviation of discriminator thresholds for the whole system is only 87 el. rms. The obtained results show that the energy resolution and uniformity of analog parameters (noise, gain, offset) are sufficient for medical diagnostic applications such as dual energy mammography and angiography.

Publikacje, które mogą Cię zainteresować

fragment książki
#34582Data dodania: 8.10.2007
RX64DTH – a fully integrated 64-channel ASIC for digital X-ray imaging system with energy window selection / P. GRYBOŚ, A. E. Cabal Rodriguez, W. DĄBROWSKI, M. IDZIK, J. Lopez Gaitan, F. Prino, L. Ramello, K. ŚWIENTEK, P. WIĄCEK // W: 2004 IEEE [Dokument elektroniczny] : NSS'04 Sessions ; MIC'04 Sessions ; RTSD'04 Sessions ; SNPS'04 Sessions : 16–22 October 2004, Rome, Italy : [special focus workshop] / guest ed. Tony Seibert ; IEEE, Nuclear & Plasma Sciences Society. — Wersja do Windows. — Dane tekstowe. — Piscataway, NJ : The Institute of Electrical and Electronics Engineers, Inc., cop. 2004. — 1 dysk optyczny. — (IEEE conference record – Nuclear Science Symposium & Medical Imaging Conference ; ISSN 1082-3654). — (CD-ROM). — e-ISBN: 0-7803-8701-5. — S. [1–5]. — Wymagania systemowe: Adobe Acrobat Reader ; napęd CD-ROM. — Bibliogr. s. [5], Abstr. — Dostęp również online: https://ieeexplore-1ieee-1org-10000479z003a.wbg2.bg.agh.edu.pl/stamp/stamp.jsp?tp=&arnumber=1462170. — S. 147–151. — Wymagania systemowe: Adobe Acrobat Reader. — Bibliogr. s. 151, Abstr.
artykuł
#35928Data dodania: 11.12.2007
Development of a fully intgrated readout system for high count rate position-sensitive measurements of X-rays using silicon strip detectors / Paweł GRYBOŚ, Władysław DĄBROWSKI // IEEE Transactions on Nuclear Science ; ISSN 0018-9499. — 2001 — vol. 48 no. 3, s. 466–472. — Bibliogr. s. 472, Abstr.