Szczegóły publikacji

Opis bibliograficzny

Influence of different types of heating systems on particulate air pollutant deposition: the case of churches situated in a cold climate / Zoya Spolnik, Anna Worobiec, Lucyna SAMEK, László Bencs, Konstantin Belikov, René Van Grieken // Journal of Cultural Heritage ; ISSN 1296-2074. — 2007 — vol. 8 iss. 1, s. 7–12. — Bibliogr. s. 12, Abstr. — Publikacja dostępna online od: 2007-03-13


Autorzy (6)

  • Spolnik Zoya
  • Worobiec Anna
  • AGHSamek Lucyna
  • Bencs László
  • Belikov Konstantin
  • van Grieken Rene

Słowa kluczowe

particulate pollutionchurchaerosolheating systemsingle particleEDXRFEPMAchemical analysis

Dane bibliometryczne

ID BaDAP33109
Data dodania do BaDAP2007-05-29
Tekst źródłowyURL
DOI10.1016/j.culher.2006.09.003
Rok publikacji2007
Typ publikacjiartykuł w czasopiśmie
Otwarty dostęptak
Czasopismo/seriaJournal of Cultural Heritage

Abstract

The influence of three types of heating systems (electrically heated pews, hot air blow heating and provisory electrical (infrared) heaters) on the transport and deposition of particulate pollution was investigated in churches located in a cold climate. Two methods were applied for the analysis of aerosol samples collected inside and outside the churches: energy dispersive X-ray fluorescence analysis and electron probe X-ray microanalysis. The results show that all the heating systems re-suspend the particulate matter brought from outside. However, the extent of re-suspension of the systems is different. It is also shown that the hot air blow heating, - the oldest design of the studied systems, - warming the church by blowing in hot air could generate organic particles. Such particles can cause soiling, and/or blackening of works of art present in the church. The application of this heating system also provoked the deterioration of the plastered walls, thus leading to the creation of an extra internal source of Ca. The other two heating systems (more modern) demonstrate less influence on the works of art regarding aerosol deposition. (c) 2007 Elsevier Masson SAS. All rights reserved.

Publikacje, które mogą Cię zainteresować

artykuł
Effects of IR heating on distribution and transport of gaseous air pollutants in urban and mountain churches in Poland / László Bencs, Zoya Spolnik, Anna Worobiec, Lucyna SAMEK, Bernhard A. H. G. Jütte, René Van Grieken // Journal of Cultural Heritage ; ISSN 1296-2074. — 2019 — vol. 36, s. 200–209. — Bibliogr. s. 208–209, Abstr. — Publikacja dostępna online od: 2018-10-06
fragment książki
Influence of different types of heating system on particulate and gaseous pollutant deposition: the case of churches situated in a cold climate / Z. Spolnik, A. Worobiec, L. Bencs, L. SAMEK, V. Kontozova, R. Van Grieken // W: IAQ in museums and archives : 6th Indoor Air Quality 2004 meeting (IAQ2004) : Padova, Italy 10–12 November 2004. — [Italy : s. n.], [2004]. — S. [1]. — Bibliogr. s. [1]