Szczegóły publikacji

Opis bibliograficzny

Refreshable mercury film silver based electrode for determination of chromium(VI) using catalytic adsorptive stripping voltammetry / Bogusław BAŚ // Analytica Chimica Acta ; ISSN  0003-2670 . — 2006 — vol. 570 iss. 2, s. 195–201. — Bibliogr. s. 201, Abstr. — Publikacja dostępna online od: 2006-05-23

Autor

Słowa kluczowe

chromium speciationmercury film electrodesvoltammetryhanging mercury drop electrodewater analysissilver amalgams

Dane bibliometryczne

ID BaDAP28120
Data dodania do BaDAP2006-06-23
Tekst źródłowyURL
DOI10.1016/j.aca.2006.04.013
Rok publikacji2006
Typ publikacjiartykuł w czasopiśmie
Otwarty dostęptak
Czasopismo/seriaAnalytica Chimica Acta

Abstract

The refreshable mercury film silver based electrode Hg(Ag)FE applied for determination of Cr(VI) traces using catalytic adsorptive striping voltammetry (CAdSV) will be presented. The film electrode is characterized by its very good surface reproducibility (not less than 2%) and long-term stability (1500–2000 measurement cycles). The mechanical refreshing of mercury film is realized in the specially constructed device, in a time shorter than 1–2 s. In the paper, it will be proved that a mechanically weak hanging mercury drop electrode (HMDE) may be substituted by mercury film Hg(Ag)FE electrode with a surface area adjustable from 1.5 to 12 mm2. For the electrode surface 4 mm2 the detection limit obtained for Cr(VI) was 0.19 nM, while the linearity range measured for a 20 s accumulation time was between 0.5 and 50 nM. The relative standard deviation (R.S.D.) in determination of Cr(VI) varied from 1 to 5%. The influence of the excess of Cr(III) on determination of Cr(VI) was analyzed using samples from the Dobczyce reservoir spiked with known amounts of Cr(VI) and Cr(III).

Publikacje, które mogą Cię zainteresować

artykuł
#35228Data dodania: 6.11.2007
Elimination of SAS interferences in catalytic adsorptive stripping voltammetric determination of $Cr(VI)$ by means of fumed silica / Ewa NIEWIARA, Bogusław BAŚ, Władysław W. KUBIAK // Electroanalysis : an International Journal Devoted to Fundamental and Practical Aspects of Electroanalysis ; ISSN 1040-0397. — 2007 — vol. 19 iss. 21, s. 2185–2193. — Bibliogr. s. 2192–2193, Abstr. — Publikacja dostępna online od: 2007-09-18
artykuł
#38816Data dodania: 28.4.2008
The renovated silver ring electrode in determination of lead traces by differential pulse stripping voltammetry / Bogusław BAŚ, Małgorzata JAKUBOWSKA // Analytica Chimica Acta ; ISSN 0003-2670. — 2008 — vol. 615 iss. 1, s. 39–46. — Bibliogr. s. 45–46, Abstr. — Publikacja dostępna online od: 2008-03-28