Szczegóły publikacji

Opis bibliograficzny

Safety of pulsed-field ablation combined with IVUS-guided pulmonary vein stenting during atrial fibrillation ablation: a case report / Tomasz JADCZYK, Lorenzo Caratti di Lanzacco, Julian Jarman, Jonathan Hill, Vias Markides // European Heart Journal. Case Reports [Dokument elektroniczny]. — Czasopismo elektroniczne ; ISSN  2514-2119 . — 2026 — vol. 10 iss. 8 art. no. ytag542, s. 1-6. — Wymagania systemowe: Adobe Reader. — Bibliogr. s. 6, Abstr. — Publikacja dostępna online od: 2026-07-18. — T. Jadczyk - dod. afiliacja: Heart Rhythm Centre, Royal Brompton and Harefield Hospitals, London, UK; School of Biomedical Engineering and Imaging Sciences, King's College London, UK; Medical University of Silesia, Katowice, Poland

Autorzy (5)

Słowa kluczowe

pulmonary vein stenosisintravascular ultrasoundcase reportpulmonary vein stentingpulsed-field ablationatrial fibrillation

Dane bibliometryczne

ID BaDAP169861
Data dodania do BaDAP2026-10-07
Tekst źródłowyURL
DOI10.1093/ehjcr/ytag542
Rok publikacji2026
Typ publikacjiartykuł w czasopiśmie
Otwarty dostęptak
Czasopismo/seriaEuropean Heart Journal. Case Reports

Abstract

Background Pulmonary vein stenosis (PVS) is an uncommon but serious complication of atrial fibrillation (AF) ablation. Angioplasty with stent implantation is the standard treatment for severe PVS; however, restenosis and re-occlusion remain frequent challenges. Pulsed-field ablation (PFA), a novel non-thermal ablation modality for pulmonary vein isolation, causes minimal structural damage and may therefore be particularly suitable and safer for complex redo procedures involving previously stenosed pulmonary veins. Case summary A 50-year-old man underwent pulmonary vein isolation using radiofrequency in February 2023. A few months later, he developed breathlessness, and a computed tomography scan showed a stenosis of the left inferior pulmonary vein (LIPV) and normal coronary arteries. He also had recurrent arrhythmias. In March 2024, with a cerebral protection device in situ and following pre-dilatation of a tight stenosis of the LIPV, an 8 × 19 mm Omnilink Elite (Abbott) stent was deployed with a good angiographic result. Reconnections of all pulmonary veins except the LIPV were targeted with radiofrequency energy but the LIPV was not treated for fear of causing further problems with stenosis. He was reviewed in December 2024 and was free from breathlessness but had recurrent palpitations. By spring 2025, he had also become breathless, and imaging showed subtotal occlusion of the LIPV stent with reduced perfusion of the left lower lobe despite continuation of edoxaban and clopidogrel after initial stenting. In May 2025, he was admitted for intravascular ultrasound (IVUS)-guided balloon angioplasty with a 7-mm drug-eluting balloon following pre-dilatation, which successfully restored stent patency. PFA was then performed on all pulmonary veins, including around the previously stented LIPV, avoiding direct catheter contact with the stent. The procedure and recovery were uneventful, and the patient’s symptoms improved markedly. He remained free from arrhythmias in April 2026 (∼1 year follow-up). Discussion This case highlights the complexity of managing AF ablation-related PVS and underscores the role of IVUS in guiding revascularization. It also demonstrates the safety of PFA (in particular Varipulse™, J&J MedTech) near a stented pulmonary vein, achieving effective electrical isolation with minimal additional structural injury.