Methodology for time and TOT calibration of a modular J-PET scanner with prompt gamma emitters 22Na and 44Sc / Krzysztof Kacprzak, [et al.], Jakub HAJDUGA, [et al.], Bartłomiej RACHWAŁ, [et al.], Tomasz SZUMLAK, [et al.] // Bio-Algorithms and Med-Systems / Jagiellonian University. Medical College ; ISSN  1895-9091 . — 2026 — vol. 22 no. 1, s. 36–55. — Bibliogr. s. 53–55, Abstr. — Publikacja dostępna online od: 2026-04-22

Autorzy (40)

Słowa kluczowe

sodiumscandiumpositron emission tomographymedical imagingmodular J-PET

Dane bibliometryczne

ID BaDAP167801
Data dodania do BaDAP2026-06-16
Tekst źródłowyURL
DOI10.5604/01.3001.0055.6703
Rok publikacji2026
Typ publikacjiartykuł w czasopiśmie
Otwarty dostęptak
Creative Commons
Czasopismo/seriaBio-Algorithms and Med-Systems

Abstract

Objective: The goal of the work is to develop a set of methods for calibrating the positron emission tomography system built from plastic scintillators, and to present the results of the modular J-PET scanner time of flight (TOF) and time over threshold (TOT) synchronisation. Methods: Measurements with radionuclide 22Na and 44Sc (used as a point-like source and enclosed in a collimator) were performed using the modular J-PET scanner, which detects signals from annihilation photons and prompt gamma. The data were gathered with a trigger-less data acquisition system and analysed with a dedicated software framework. The detection modules were synchronised with the procedures, correcting time offsets and normalising TOT measurements. Results: The application of the time calibration methods yields a fully synchronised detector that is capable of producing the image of the source. TOF resolution for modular J-PET is determined to be about 490 ps (FWHM). Conclusions: The J-PET scanner, built from plastic scintillators, can be calibrated using β+γ emitters and taking advantage of the fact that the direction of propagation of annihilation and prompt photons are not correlated.

Publikacje, które mogą Cię zainteresować

artykuł
#167014Data dodania: 27.4.2026
First positronium imaging using $^{44}Sc$ with the J-PET scanner: a case study on the NEMA-image quality phantom / Manish Das, [et al.], Jakub HAJDUGA, [et al.], Bartłomiej RACHWAŁ, [et al.], Tomasz SZUMLAK, [et al.] // IEEE Transactions on Radiation and Plasma Medical Sciences ; ISSN  2469-7311 . — 2026 — vol. 10 no. 4, s. 593–602. — Bibliogr. s. 600–602, Abstr. — Publikacja dostępna online od: 2025-10-14
artykuł
#101664Data dodania: 6.12.2016
Oblique-viewing endoscope calibration in the diagnostics and treatment in the pelvis minor area / Krzysztof HOLAK, Piotr KOHUT, Klaudia Stangel-Wojcikiewicz, Monika Kabzińska-Turek, Joanna FLORCZAK, Maciej PETKO // Bio-Algorithms and Med-Systems / Jagiellonian University. Medical College ; ISSN 1895-9091. — 2016 — vol. 12 iss. 3, s. 133–140. — Bibliogr. s. 140, Abstr. — Publikacja dostępna online od: 2016-08-08