Szczegóły publikacji

Opis bibliograficzny

Clinical assessment of a method for comparative analysis of planned vs. delivered isodoses in radiation therapy / Paweł Wołowiec, Mateusz BARAN, Piotr Pedrycz, Rafał Stando, Krzysztof RZECKI, Tomasz SOŚNICKI, Zbisław TABOR // Reports of Practical Oncology and Radiotherapy ; ISSN  1507-1367 . — 2025 — vol. 30 no. 5, s. 642–648. — Bibliogr. s. 648, Abstr. — Publikacja dostępna online od: 2025-09-08

Autorzy (7)

Słowa kluczowe

dose-volume histogramquality assurancegamma analysisdose distribution

Dane bibliometryczne

ID BaDAP164842
Data dodania do BaDAP2025-12-16
Tekst źródłowyURL
DOI10.5603/rpor.108007
Rok publikacji2025
Typ publikacjiartykuł w czasopiśmie
Otwarty dostęptak
Creative Commons
Czasopismo/seriaReports of Practical Oncology and Radiotherapy

Abstract

Background: The effectiveness of external beam photon radiotherapy relies on precise planning and execution, involving patient-specific quality assurance to ensure clinical goals are met. This involves verifying the therapy plan against constraints set by the oncology team and confirming its correct implementation. Standard QA methods include gamma analysis and dose-volume histograms (DVH), each with limitations. Gamma analysis highlights delivery errors without distinguishing between over- and under-dosage, while DVH can show coinciding planned and delivered doses despite spatial distribution differences. In this work, a novel method, quantitative isodose analysis, is evaluated on treatment plans with the purpose of determining whether it can address these limitations, and assessing their clinical significance. Materials and methods: Quantitative isodose analysis works by comparing planned and delivered isodoses for each structure, identifying volumes of under- and over-dosage. This method was validated using anonymized patient data involving 75 treatment plans for different cancer locations. Results: In a prostate cancer case, significant rectal overdosage was detected, leading to a treatment plan revision. Another rectal cancer case showed underdosage but met clinical implementation criteria. Conclusions: Results showed that quantitative isodose analysis could detect clinically significant dose delivery errors that standard QA might miss. The findings suggest that while standard QA methods are essential, quantitative isodose analysis provides an additional layer of scrutiny, enhancing the detection of dose discrepancies. The study highlights the potential of quantitative isodose analysis in improving radiotherapy QA, despite limitations such as reliance on reconstructed 3D dose distributions and the need for broader patient cohort studies.

Publikacje, które mogą Cię zainteresować

artykuł
#146734Data dodania: 17.5.2023
Isodoses – a set theory-based patient-specific QA measure to compare planned and delivered isodose distributions in photon radiotherapy / Mateusz BARAN, Zbisław TABOR, Damian Kabat, Monika Tulik, Kinga Jeleń, Krzysztof RZECKI, Bohdan Forostianyi, Konrad Bałabuszek, Robert Koziarski, Michael P. R. Waligórski // Strahlentherapie und Onkologie ; ISSN  0179-7158 . — 2022 — vol. 198 iss. 9, s. 849–861. — Bibliogr. s. 861, Abstr. — Publikacja dostępna online od: 2022-06-22. — M. Baran, Z. Tabor, K. Rzecki – dod. afiliacja: Cracow University of Technology
artykuł
#157866Data dodania: 28.1.2025
The method of radiation risk assessment based on physico-geographical regionalisation: a case study of Carpathians, Poland / Filip JĘDRZEJEK, Katarzyna SZARŁOWICZ, Marcin STOBIŃSKI // Environmental Science and Pollution Research ; ISSN 0944-1344. — 2024 — vol. 31 iss. 57, s. 65533–65547. — Bibliogr. s. 65545–65547, Abstr. — Publikacja dostępna online od: 2024-11-25