Szczegóły publikacji

Opis bibliograficzny

Performance of acoustic, electro-acoustic and optical sensors in precise waveform analysis of a plucked and struck guitar string / Jan JASIŃSKI, Marek PLUTA, Roman TROJANOWSKI, Julia Grygiel, Jerzy WICIAK // Sensors [Dokument elektroniczny]. — Czasopismo elektroniczne ; ISSN 1424-8220. — 2025 — vol. 25 iss. 21 art. no. 6514, s. 1–24. — Wymagania systemowe: Adobe Reader. — Bibliogr. s. 23–24, Abstr. — Publikacja dostępna online od: 2025-10-22

Autorzy (5)

Słowa kluczowe

laser Doppler vibrometerstring vibrationLDVnon contact sensingsensor comparisonmusical acousticselectric guitarelectro-acoustic transducerwaveform analysis

Dane bibliometryczne

ID BaDAP163977
Data dodania do BaDAP2025-11-24
Tekst źródłowyURL
DOI10.3390/s25216514
Rok publikacji2025
Typ publikacjiartykuł w czasopiśmie
Otwarty dostęptak
Creative Commons
Czasopismo/seriaSensors

Abstract

This study presents a comparative performance analysis of three sensor technologies—microphone, magnetic pickup, and laser Doppler vibrometer—for capturing string vibration under varied excitation conditions: striking, plectrum plucking, and wire plucking. Two different magnetic pickups are included in the comparison. Measurements were taken at multiple excitation levels on a simplified electric guitar mounted on a stable platform with repeatable excitation mechanisms. The analysis focuses on each sensor’s capacity to resolve fine-scale waveform features during the initial attack while also taking into account its capability to measure general changes in instrument dynamics and timbre. We evaluate their ability to distinguish vibro-acoustic phenomena resulting from changes in excitation method and strength as well as measurement location. Our findings highlight the significant influence of sensor choice on observable string vibration. While the microphone captures the overall radiated sound, it lacks the required spatial selectivity and offers poor SNR performance 34 dB lower then other methods. Magnetic pickups enable precise string-specific measurements, offering a compelling balance of accuracy and cost-effectiveness. Results show that their low-pass frequency characteristic limits temporal fidelity and must be accounted for when analysing general sound timbre. Laser Doppler vibrometers provide superior micro-temporal fidelity, which can have critical implications for physical modeling, instrument design, and advanced audio signal processing, but have severe practical limitations. Critically, we demonstrate that the required optical target, even when weighing as little as 0.1% of the string’s mass, alters the string’s vibratory characteristics by influencing RMS energy and spectral content.

Publikacje, które mogą Cię zainteresować

artykuł
#159873Data dodania: 16.6.2025
Coupling of limit switch sensors and stepper motors with acoustic feedback for positioning of a cartesian robot end effector in the study of musical instruments / Daniel TOKARCZYK, Jan JASIŃSKI, Marek PLUTA, Jerzy WICIAK // Sensors [Dokument elektroniczny]. — Czasopismo elektroniczne ; ISSN 1424-8220. — 2025 — vol. 25 iss. 6 art. no. 1709, s. 1–20. — Wymagania systemowe: Adobe Reader. — Bibliogr. s. 19–20, Abstr. — Publikacja dostępna online od: 2025-03-10
artykuł
#165129Data dodania: 9.1.2026
The effect of micro-changes in the pluck trajectory on the sound of an acoustic guitar / Marek PLUTA, Jan JASIŃSKI, Daniel TOKARCZYK, Julia Grygiel // Vibrations in Physical Systems = Drgania w Układach Fizycznych ; ISSN  0860-6897 . — 2025 — vol. 36 no. 2 art. no. 2025205, s. 1–14. — Bibliogr. s. 13–14, Abstr.