Szczegóły publikacji

Opis bibliograficzny

Measurement uncertainty of sound absorption coefficient measured in a 1:8 scale reverberation room / Aleksandra CHOJAK // Vibrations in Physical Systems = Drgania w Układach Fizycznych ; ISSN 0860-6897. — 2025 — vol. 36 no. 1 art. no. 2025104, s. 1–8. — Bibliogr. s. 8, Abstr.

Autor

Słowa kluczowe

similitudeacoustic measurementsMonte Carlo simulations

Dane bibliometryczne

ID BaDAP163200
Data dodania do BaDAP2025-10-03
Tekst źródłowyURL
DOI10.21008/j.0860-6897.2025.1.04
Rok publikacji2025
Typ publikacjiartykuł w czasopiśmie
Otwarty dostęptak
Creative Commons
Czasopismo/seriaVibrations in Physical Systems = Drgania w Układach Fizycznych

Abstract

The measurements of sound absorption coefficient in a scaled reverberation room are mainly used for the purpose of choosing the materials for acoustic scale models. Another application of scale model measurements of sound absorption coefficient is testing multiple variants and modifications of special acoustic elements, once their scale equivalents are found. Regardless of the purpose of the sound absorption measurement, the measurement accuracy should be known, and therefore it is necessary to determine the measurement uncertainty budget. The measurement procedure is based on the one described in the ISO 354 standard, which means that the measurement of sound absorption coefficient is an indirect type of measurement, and the final measurement uncertainty depends on the uncertainties of all the measured input values. The paper describes an approach to determining measurement uncertainty of sound absorption coefficient measured in a 1:8 reverberation room with the propagation of distributions using the Monte Carlo method. The sensitivity analysis of the final uncertainty is also analyzed with regard to all the measured input values, such as the reverberation time, relative air humidity, air temperature, and the size of the sample. The obtained results show that the measurement uncertainty of the sound absorption coefficient measured in a 1:8 scale reverberation room is comparable to the measurement uncertainty of full-scale measurements and does not change significantly depending on the measurement conditions.

Publikacje, które mogą Cię zainteresować

artykuł
#158859Data dodania: 23.4.2025
The impact of diffuser arrangement in a reverberation room on airborne sound insulation measurements / Dominik MLECZKO, Kinga Sapieja // Vibrations in Physical Systems = Drgania w Układach Fizycznych ; ISSN 0860-6897. — 2024 — vol. 35 no. 3, s. 1–10. — Bibliogr. s. 9–10, Abstr.
artykuł
#142981Data dodania: 14.10.2022
Analysis of factors influencing the measurement result of the reverberant sound absorption coefficient under laboratory conditions / Marcjanna CZAPLA, Tadeusz WSZOŁEK // Vibrations in Physical Systems = Drgania w Układach Fizycznych ; ISSN 0860-6897. — 2022 — vol. 33 no. 1, s. 1–10. — Bibliogr. s. 9–10, Abstr.