Szczegóły publikacji

Opis bibliograficzny

An experimental investigation of twelve concrete beams post-tensioned with unbonded tendons under center-point and third-point loading / Wojciech POLITALSKI, Andrzej Seruga // Materials [Dokument elektroniczny]. — Czasopismo elektroniczne ; ISSN  1996-1944 . — 2025 — vol. 18 iss. 18 art. no. 4333, s. 1-26. — Wymagania systemowe: Adobe Reader. — Bibliogr. s. 24-26, Abstr. — Publikacja dostępna online od: 2025-09-16

Autorzy (2)

Słowa kluczowe

flexural capacityprestressed concreteultimate stresstendon stress increasebending resistanceunbonded tendons

Dane bibliometryczne

ID BaDAP162935
Data dodania do BaDAP2025-09-25
Tekst źródłowyURL
DOI10.3390/ma18184333
Rok publikacji2025
Typ publikacjiartykuł w czasopiśmie
Otwarty dostęptak
Creative Commons
Czasopismo/seriaMaterials

Abstract

The first concrete structures post-tensioned with unbonded tendons were constructed in the 1950s. Despite the popularity of such a type of construction solution, the theory describing the behavior of members with unbonded prestress remains relatively unknown. Different standards, provisions, and theories described by scientists can be found in the literature. The main problem is related to determining the value of the prestressing force and its increments because it is dependent upon the member rather than the section due to a lack of bond between the concrete and the tendons. Both theoretical and experimental studies enable the definition of parameters that have an influence on stress increase. Three of the most important of these parameters were investigated in tests conducted by the authors. This paper presents the findings of an experimental study conducted on twelve simply supported RC beams that were prestressed with unbonded tendons. A total of twelve elements were grouped according to various criteria, including their span-to-depth ratio, prestressed reinforcement ratio, and type of loading. All beams had a low reinforcing bars index, which met the Eurocode 2 requirements. The aim of this research was to check if such a level of ordinary reinforcement ratio will enable the achievement of a satisfactory crack pattern and also a high stress increase in unbonded tendons. The members were tested to investigate their behavior and the stress increment in tendons in terms of their load-carrying capacity.

Publikacje, które mogą Cię zainteresować

artykuł
#156841Data dodania: 11.1.2025
Post-tensioned hollow-core concrete slabs with unbonded tendons for truck scale platforms: design assumptions and tests / Rafał Stanisław Szydłowski, Barbara Łabuzek, Łukasz BEDNARSKI // Materials [Dokument elektroniczny]. — Czasopismo elektroniczne ; ISSN 1996-1944. — 2024 — vol. 17 iss. 16 art. no. 4154, S. 1-14. — Wymagania systemowe: Adobe Reader. — Bibliogr. s. 13-14, Abstr. — Publikacja dostępna online od: 2024-08-22