Szczegóły publikacji

Opis bibliograficzny

A robust automatic generation control system based on Hybrid Aquila Optimizer-Sine Cosine algorithm / Sadeq D. Al-Majidi, Al-hussein M. Alturfi, Mohammed Kh. Al-Nussairi, Rasha Abed Hussein, Rohit SALGOTRA, Maysam F. Abbod // Results in Engineering [Dokument elektroniczny]. — Czasopismo elektroniczne ; ISSN 2590-1230. — 2025 — vol. 25 art. no. 103951, s. 1–18. — Wymagania systemowe: Adobe Reader. — Bibliogr. s. 17–18, Abstr. — Publikacja dostępna online od: 2025-01-11

Autorzy (6)

  • Al-Majidi Sadeq D.
  • Alturfi Al hussein M.
  • Al-Nussairi Mohammed Kh.
  • Hussein Rasha Abed
  • AGHSalgotra Rohit
  • Abbod Maysam F.

Słowa kluczowe

Proportional Integral Derivativepower system networksine cosine algorithmaquila optimizerautomatic generation controller

Dane bibliometryczne

ID BaDAP160855
Data dodania do BaDAP2025-07-03
Tekst źródłowyURL
DOI10.1016/j.rineng.2025.103951
Rok publikacji2025
Typ publikacjiartykuł w czasopiśmie
Otwarty dostęptak
Creative Commons
Czasopismo/seriaResults in Engineering

Abstract

The fluctuating frequency in a power grid is the major stability challenge duo to the unpredictable power demand of costumers during the time. To address this issue, automatic generation controller (AGC) is employed. The AGC based on a proportional integral derivative (PID) approach is popularly utilised owing to its soft implementation and lower expenditure. However, it ripples to handle the standard frequency of a multi-area power grid that occurs in a competitive load-demand case, because of the high sensitivity of its uncertain parameters. In this paper, a Hybrid Aquila Optimizer-Sine Cosine algorithm (HSCAO) is designed for addressing the sensitivity of the PID-AGC parameters specifically for the multi-area power system network. The suggested algorithm is assessed based on CEC-2019, and classical benchmark issues with various dimensions to validate its performance and address the better fits of the algorithm parameters adequately. Also, a statistical analysis technique is conducted using Wilcoxon's test and Friedman test to demonstrate the supervise performance of the HSCAO optimisation regarding to other relative optimal algorithms. A two-area power system network is simulated using MATLAB environment to implement the proposed AGC system. The outcomes prove that the optimal PID-AGC method based on HSCAO technique demonstrates its ability to address the simple and complex fluctuations of load demands quickly. Also, it is the most robust to supervise the frequency response under fault condition test, resulting in, achieving the lowest ITAE index of 5.2s compared to the conventional fuzzy logic control-AGC and the conventional PID-AGC of 10.9s and 17.4s respectively. © 2025 The Author(s)

Publikacje, które mogą Cię zainteresować

artykuł
#140141Data dodania: 16.5.2022
A hybrid feature selection framework using improved sine cosine algorithm with metaheuristic techniques / Lichao Sun, Hang Qin, Krzysztof Przystupa, Yanrong Cui, Orest Kochan, Mikołaj SKOWRON, Jun Su // Energies [Dokument elektroniczny]. — Czasopismo elektroniczne ; ISSN 1996-1073. — 2022 — vol. 15 iss. 10 art. no. 3485, s. 1–24. — Wymagania systemowe: Adobe Reader. — Bibliogr. s. 23–24, Abstr. — Publikacja dostępna online od: 2022-05-10