Optimisation of the operating voltage of a multilayer uniaxial dielectric elastomer generator / Wojciech SIKORA, Krzysztof MICHALCZYK // Advances in Science and Technology Research Journal [Dokument elektroniczny]. — Czasopismo elektroniczne ; ISSN 2299-8624. — 2025 — vol. 19 iss. 6, s. 203–214. — Wymagania systemowe: Adobe Reader. — Bibliogr. s. 213–214, Abstr.

Autorzy (2)

Słowa kluczowe

energy harvestingDEGdielectric elastomer generatoruniaxialoptimization

Dane bibliometryczne

ID BaDAP159803
Data dodania do BaDAP2025-06-11
Tekst źródłowyURL
DOI10.12913/22998624/202767
Rok publikacji2025
Typ publikacjiartykuł w czasopiśmie
Otwarty dostęptak
Creative Commons
Czasopismo/seriaPostępy Nauki i Techniki

Abstract

The optimum operating parameters for dielectric elastomer generator (DEG) systems, in the sense of the global optimum, refer to their maximum performance in terms of elastomer tensile strength, breakdown voltage value etc. In practice, operating a DEG close to the limit of its strength will involve a limitation of its durability, as DEGs can also suffer fatigue damage. Deviation from the optimum operating parameters, either for reasons of increasing their durability and reliability or simply because of practical limitations in a given application, makes it necessary to search for local optimum operating points. The aim of this study was to analytically determine the optimum working point of a DEG generator operating in a rectangular cycle (constant charge, constant voltage) by the value of the voltage difference between the upper and lower sources. On the basis of capacitance measurements on two generators with two and three active layers (electrodes) operating under uniaxial tensile loading, the theoretical values of the optimal voltage difference ΔU were calculated. The results were then verified experimentally. The empirical values were found to be in agreement with the theory (Fig. 10) and showed that it is possible to predict the performance of a DEG accurately by knowing the variations in its electrical capacitance.

Publikacje, które mogą Cię zainteresować

artykuł
#147800Data dodania: 27.7.2023
Experimental investigation of a uniaxial dielectric elastomer generator / Wojciech SIKORA // Acta Mechanica et Automatica ; ISSN 1898-4088. — 2023 — vol.17 no. 4, s. 499–506. — Bibliogr. s. 505–506, Abstr.
fragment książki
#154422Data dodania: 15.7.2024
Estimating the capacitance of a dielectric elastomer generator using selected measurement methods / Wojciech SIKORA // W: ICCC 2024 [Dokument elektroniczny] : 25th International Carpathian Control Conference : 22–24 May 2024, Krynica-Zdrój, Poland : proceedings / ed. Andrzej Kot. — Wersja do Windows. — Dane tekstowe. — Piscataway : IEEE, cop. 2024. — Dod. ISBN: 979-8-3503-5069-2, 979-8-3503-5071-5. — e-ISBN: 979-8-3503-5070-8. — S. [1–5]. — Wymagania systemowe: Adobe Reader. — Bibliogr. s. [5], Abstr. — Publikacja dostępna online od: 2024-07-01