Accuracy of bridge span measurements using classical and GNSS methods / Aleksandra MACIEJEWSKA, Ivan Brusak, Kamil MACIUK // Budownictwo i Architektura / Politechnika Lubelska ; ISSN 1899-0665. — 2025 — vol. 24 no. 1, s. 163–174. — Bibliogr. s. 172–174, Abstr. — Publikacja dostępna online od: 2025-03-31. — K. Maciuk - dod. afiliacja: Department of Higher Geodesy and Astronomy, Lviv Polytechnic National University, Lviv, Ukraine

Autorzy (3)

Słowa kluczowe

bridge spansdeflection measurementtacheometrystatic GNSS measurement

Dane bibliometryczne

ID BaDAP159255
Data dodania do BaDAP2025-04-07
Tekst źródłowyURL
DOI10.35784/bud-arch.6321
Rok publikacji2025
Typ publikacjiartykuł w czasopiśmie
Otwarty dostęptak
Creative Commons
Czasopismo/seriaBudownictwo i Architektura

Abstract

The primary objective of the authors was to measure the deflection of a bridge span using two different methods and to draw conclusions from the analysis of the results. The Millennium Bridge in Wroclaw was selected as the test object. The bridge was surveyed using both classical geodetic techniques (tacheometry) and a static Global Navigation Satellite System (GNSS) survey. Due to the requirements of both surveying methods, it was necessary to establish a control consisting of five points. Three of these were located on the bridge and were used for displacement measurements, while the other two points were used for control. The article describes the field and office work, considering the measurement process and its analysis. Based on the results, the application of these techniques yielded different values, which influenced their final interpretation. The displacements in the Up, East, and North components are 0.013, 0.011, and 0.032 m by the GNSS technique and 0.002, 0.015, and 0.002 m by tacheometry for the P1, P2, and P3 points, respectively. Furthermore, in the case of the static GNSS measurement, the errors for each displacement did not indicate that any of them was significant according to the three-sigma rule, calculated in relation to the value of each component or point. However, the classical method showed that the displacement at point P2 is significant and is the only one that could have a real impact on the use of the bridge. The result also confirms that a combination of different geodetic technologies, both classical and GNSS, can be effectively used for monitoring cable-stayed bridges.

Publikacje, które mogą Cię zainteresować

fragment książki
#156299Data dodania: 27.11.2024
Classical and GNSS survey of bridge span deflection / Aleksandra MACIEJEWSKA, Ivan Brusak, Kamil MACIUK // W: XXIV CPSYS [Dokument elektroniczny] : Conference of PhD Students and Young Scientists : interdisciplinary topics in mining, geology and geomatics : Wrocław, October 23 – 25, 2024, hybrid event : book of abstracts. — Wersja do Windows. — Dane tekstowe. — Wrocław : Wrocław University of Science and Technology Publishing House, [2024]. — e-ISBN: 978-83-7493-249-3. — S. [1]. — Wymagania systemowe: Adobe Reader. — Tryb dostępu: https://cpsys.pwr.edu.pl/abstracts2024/358_GE_O_1.pdf [2024-10-29]. — K. Maciuk - dod. afiliacja: Lviv Polytechnic National University, Karpinsky, Lviv, Ukraine
artykuł
#127348Data dodania: 17.2.2020
The problem of GNSS positioning with measurements recorded using Android mobile devices / Bogdan SKORUPA // Budownictwo i Architektura / Politechnika Lubelska ; ISSN 1899-0665. — 2019 — vol. 18 no. 3, s. 51–61. — Bibliogr. s. 59–61, Abstr.