Szczegóły publikacji

Opis bibliograficzny

14 MeV calibration of JET neutron detectors—phase 2: in-vessel calibration / P. Batistoni, S. Popovichev, Z. Ghani, A. Cufar, L. Giacomelli, P. Hawkins, K. Keogh, S. Jednorog, E. Łaszyńska, S. Loreti, A. Peacock, M. Pillon, R. Price, A. Reed, D. Rigamonti, J. Stephens, J. Bielecki, S. Conroy, J. Dankowski, V. Krasilnikov // Nuclear Fusion ; ISSN 0029-5515. — 2018 — vol. 58 no. 10 art. no. 106016, s. 1–16. — Bibliogr. s. 15–16, Abstr. — Publikacja dostępna online od: 2018-08-03. — E. Łaszyńska - afiliacja: Institute of Plasma Physics and Laser Microfusion, Warsaw

Autorzy (20)

  • Batistoni Paolo
  • Popovichev Sergey
  • Ghani Zamir
  • Cufar A.
  • Giacomelli L.
  • Hawkins P.
  • Keogh K.
  • Jednoróg Sławomir
  • Łaszyńska Ewa
  • Loreti S.
  • Peacock A.
  • Pillon Mario
  • Price R.
  • Reed A.
  • Rigamonti D.
  • Stephens J.
  • Bielecki Jakub
  • Conroy Sean
  • Dankowski J.
  • Krasilnikov V.

Słowa kluczowe

fusion power measurementneutron calibrationfusion reactor

Dane bibliometryczne

ID BaDAP158831
Data dodania do BaDAP2025-04-05
Tekst źródłowyURL
DOI10.1088/1741-4326/aad4c1
Rok publikacji2018
Typ publikacjiartykuł w czasopiśmie
Otwarty dostęptak
Czasopismo/seriaNuclear Fusion

Abstract

A new DT campaign (DTE2) is planned at JET in 2020 to minimize the risks of ITER operations. In view of DT operations, a calibration of the JET neutron monitors at 14 MeV neutron energy has been performed using a well calibrated 14 MeV neutron generator (NG) deployed, together with its power supply and control unit, inside the vacuum vessel by the JET remote handling system. The NG was equipped with two calibrated diamond detectors, which continuously monitored its neutron emission rate during the calibration, and activation foils which provided the time integrated yield. Cables embedded in the remote handling boom were used to power the neutron generator, the active detectors and pre-amplifier, and to transport the detectors' signal. The monitoring activation foils were retrieved at the end of each day for decay γ-ray counting, and replaced by fresh ones. About 76 hours of irradiation, in 9 days, were needed with the neutron generator in 73 different poloidal and toroidal positions in order to calibrate the two neutron yield measuring systems available at JET, the 235U fission chambers (KN1) and the inner activation system (KN2). The NG neutron emission rates provided by the monitoring detectors were in agreement within 3%. Neutronics calculations have been performed using MCNP code and a detailed model of JET to derive the response of the JET neutron detectors to DT plasma neutrons starting from the response to the NG neutrons, and taking into account the anisotropy of the neutron generator and all the calibration circumstances. These calculations have made use of a very detailed and validated geometrical description of the neutron generator and of the modified MNCP neutron source subroutine producing neutron energy-angle distribution for the neutrons emitted by the NG. The KN1 calibration factor for a DT plasma has been determined with ±4.2% experimental uncertainty. Corrections due to NG and remote handling effects and the plasma volume effect have been calculated by simulation modelling. The related additional uncertainties are difficult to estimate, however the results of the previous calibration in 2013 have demonstrated that such uncertainties due to modelling are globally ±3%. It has been found that the difference between KN1 response to DD neutrons and that to DT neutrons is within the uncertainties in the derived responses. KN2 has been calibrated using the 93Nb(n,2n)92mNb and 27Al(n,a)24Na activation reactions (energy thresholds 10 MeV and 5 MeV, respectively). The total uncertainty on the calibration factors is ±6% for 93Nb(n,2n)92mNb and ±8% 27Al(n,a)24Na (1σ). The calibration factors of the two independent systems KN1 and KN2 will be validated during DT operations. The experience gained and the lessons learnt are presented and discussed in particular with regard to the 14 MeV neutron calibrations in ITER.

Publikacje, które mogą Cię zainteresować

artykuł
#158816Data dodania: 5.4.2025
14 MeV calibration of JET neutron detectors—phase 1: calibration and characterization of the neutron source / P. Batistoni, S. Popovichev, A. Cufar, Z. Ghani, L. Giacomelli, S. Jednorog, A. Klix, S. Lilley, E. Łaszynska, S. Loreti, L. Packer, A. Peacock, M. Pillon, R. Price, M. Rebai, D. Rigamonti, N. Roberts, M. Tardocchi, D. Thomas // Nuclear Fusion ; ISSN 0029-5515. — 2018 — vol. 58 no. 2 art. no. 026012, s. 1–24. — Bibliogr. s. 23–24, Abstr. — Publikacja dostępna online od: 2017-12-21. — E. Łaszyńska - afiliacja: Institute of Plasma Physics and Laser Microfusion, Warsaw
artykuł
#158827Data dodania: 5.4.2025
Activation measurements in support of the 14 MeV neutron calibration of JET neutron monitors / S. Jednorog, E. Łaszyńska, P. Batistoni, B. Bienkowska, A. Cufar, Z. Ghani, L. Giacomelli, A. Klix, S. Loreti, K. Mikszuta, L. Packe, A. Peacock, M. Pillon, S. Popovichev, M. Rebai, D. Rigamonti, N. Roberts, M. Tardocchi, D. Thomas // Fusion Engineering and Design ; ISSN 0920-3796. — Tytuł poprz.: Nuclear Engineering and Design. Fusion. — 2017 — vol. 125, s. 50–56. — Bibliogr. s. 56, Abstr. — Publikacja dostępna online od: 2017-11-02. — E. Łaszyńska - afiliacja: Institute of Plasma Physics and Laser Microfusion, Warsaw