Szczegóły publikacji

Opis bibliograficzny

Development and tests of the novel configuration of the solar chimney with sensible heat storage / Krzysztof SORNEK, Rafał FIGAJ, Karolina PAPIS-FRĄCZEK // Applied Thermal Engineering ; ISSN 1359-4311. — 2025 — vol. 258 pt. A art. no. 124515, s. 1–15. — Bibliogr. s. 14–15, Abstr. — Publikacja dostępna online od: 2024-10-01

Autorzy (3)

Słowa kluczowe

solar energyHVACsolar air heaterthermal storagesolar chimneypassive solar energyventilationheat recovery

Dane bibliometryczne

ID BaDAP155934
Data dodania do BaDAP2024-11-05
Tekst źródłowyURL
DOI10.1016/j.applthermaleng.2024.124515
Rok publikacji2025
Typ publikacjiartykuł w czasopiśmie
Otwarty dostęptak
Creative Commons
Czasopismo/seriaApplied Thermal Engineering

Abstract

Heating, ventilation, and air conditioning systems account for a significant part of the energy usage in buildings and are primarily responsible for greenhouse gas emissions and operating costs. These can be lowered by the adoption of solar energy. This paper presents the developing and testing of a novel solar chimney with sensible heat storage. The thermal performance and potential contribution of the developed thermal chimney to decreasing residential buildings energy consumption in Polish climate conditions is investigated. The developed solar air chimney is composed of a novel accumulation material that allows for sensible heat storage. Solar radiation can heat the accumulation layer during the day and the stored energy can be used to preheat the ventilation air. The prototype of the solar chimney was tested in laboratory conditions using a dedicated experimental rig. Furthermore, numerical calculations were performed using TRNSYS software, where a validated dynamic numerical model was developed to simulate the performance of the device. The results show that airflow direction, volume, and the number of heated walls significantly impact the power transferred from the solar chimney walls to the air. The maximum power transferred from the solar chimney walls to the air per unit of surface varied from 360.2 W/m2 (when all walls were heated) to 672.4 W/m2 (when only one wall was heated). The validated model underestimates the outlet air temperature of the solar chimney by a maximum of 0.39 °C on average basis and shows that the increase of air temperature between −10 and 20 °C at 1000 W/m2 determines a decrease of 12.5 % of the thermal output. The obtained results allow one to highlight that the proposed solution can be considered as a replacement for typical brick chimneys located on roofs or as a thermal storage wall.

Publikacje, które mogą Cię zainteresować

artykuł
#142032Data dodania: 9.9.2022
Development and tests of the solar air heater with thermal energy storage / Krzysztof SORNEK, Karolina PAPIS-FRĄCZEK // Energies [Dokument elektroniczny]. — Czasopismo elektroniczne ; ISSN 1996-1073. — 2022 — vol. 15 iss. 18 art. no. 6583, s. 1-20. — Wymagania systemowe: Adobe Reader. — Bibliogr. s. 19-20, Abstr. — Publikacja dostępna online od: 2022-09-08
fragment książki
#147962Data dodania: 7.8.2023
Solar air heaters with sensible heat storage for preheating ventilation air as a way to enhance building energy performance / Krzysztof SORNEK // W: ECOS 2023 [Dokument elektroniczny] : 36th international conference on Efficiency, Cost, Optimization, Simulation and environmental impact of energy systems : 25–30 June 2023, Las Palmas de Gran Canaria, Spain : proceedings book. [Pt.] 1, Preliminary version / [eds.] Ana María Blanco-Marigorta, [et al.]. — Wersja do Windows. — Dane tekstowe. — Las Palmas de Gran Canaria : ULPGC – Juan de Quesada, [2023]. — S. 461–472. — Wymagania systemowe: Adobe Reader. — Tryb dostępu: https://inscribe-t.com/wp-content/uploads/2023/07/BOOK-1-ECOS... [2023-07-28]. — Bibliogr. s. 471–472, Abstr.