Analysis of the influence of the 6-pulse thyristor-bridge input reactor size on the shunt active power filter work efficiency: a case study / Chamberlin Stéphane AZEBAZE MBOVING, Zbigniew HANZELKA // Energies [Dokument elektroniczny]. — Czasopismo elektroniczne ; ISSN 1996-1073. — 2024 — vol. 17 iss. 1 art. no. 80, s. 1–28. — Wymagania systemowe: Adobe Reader. — Bibliogr. s. 25–28, Abstr. — Publikacja dostępna online od: 2023-12-22


Autorzy (2)


Słowa kluczowe

instantaneous p-q theoryasymmetry mitigationreactive power compensationthyristor-bridge input reactorharmonics mitigationpower gridSAPF input reactorshunt active power filtercontrol systemlaboratory set uprate of current change

Dane bibliometryczne

ID BaDAP151085
Data dodania do BaDAP2024-01-22
Tekst źródłowyURL
DOI10.3390/en17010080
Rok publikacji2024
Typ publikacjiartykuł w czasopiśmie
Otwarty dostęptak
Creative Commons
Czasopismo/seriaEnergies

Abstract

This paper presents a case study in which the influence of the 6-pulse thyristor-bridge input reactor size on the shunt active power filter (SAPF)’s work performance is investigated. The purpose of using an SAPF in the power system is in most cases for fundamental harmonic reactive power compensation, harmonics and asymmetry mitigation. The work efficiency of such a filter depends not only on the designed control system, interface filter and dc-link capacitor parameters, but also on the parameters of the electrical system in which it is connected. Therefore, it is necessary to study and know the power system (supplier and consumer sides) before its installation. For instance, in the electrical system with diode or thyristor-bridge as loads, the SAPF performance efficiency may not be satisfied due to the high rate of current change (di/dt) at the points of commutation notches. In this paper, the performed simulation and laboratory experiments show that for a better operating efficiency of the SAPF, the input reactor parameters should be selected based not only on the effective reduction in the inverter switching ripple or the control system demand, but also on the parameters of the load, such as the parameters of the diode or thyristor-bridge input reactor. Apart from the experimental demonstrations on how the input reactor size influences the SAPF work efficiency, the novelties in this paper are: the formulated recommendations on how to choose the SAPF input reactor parameters (the SAPF is more efficient in terms of harmonics, asymmetry and reactive power mitigation when the inductance of its input reactor (L-filter) is smaller than the one of the diode or thyristor-bridge input reactor); the proposed SAPF control system; the proposed expressions to compute the SAPF input reactor inductance, DC voltage and capacitor.

Publikacje, które mogą Cię zainteresować

artykuł
Analysis of the factors having an influence on the $LC$ passive harmonic filter work efficiency / Chamberlin Stéphane AZEBAZE MBOVING, Zbigniew HANZELKA, Andrzej FIRLIT // Energies [Dokument elektroniczny]. — Czasopismo elektroniczne ; ISSN 1996-1073. — 2022 — vol. 15 iss. 5 art. no. 1894, s. 1–51. — Wymagania systemowe: Adobe Reader. — Bibliogr. s. 49–51, Abstr. — Publikacja dostępna online od: 2022-03-04
artykuł
Investigation on the work efficiency of the LC passive harmonic filter chosen topologies / Chamberlin Stéphane AZEBAZE MBOVING // Electronics [Dokument elektroniczny]. — Czasopismo elektroniczne ; ISSN 2079-9292. — 2021 — vol. 10 iss. 8 art. no. 896, s. 1–35. — Wymagania systemowe: Adobe Reader. — Bibliogr. s. 32–35, Abstr. — Publikacja dostępna online od: 2021-04-08