Szczegóły publikacji

Opis bibliograficzny

Rollover prevention model for stratified liquefied natural gas in storage tanks / Tomasz WŁODEK, Mariusz ŁACIAK // Energies [Dokument elektroniczny]. — Czasopismo elektroniczne ; ISSN 1996-1073. — 2023 — vol. 16 iss. 22 art. no. 7666, s. 1–23. — Wymagania systemowe: Adobe Reader. — Bibliogr. s. 21–23, Abstr. — Publikacja dostępna online od: 2023-11-20


Autorzy (2)


Słowa kluczowe

boil-off gasrolloverrollover modelevaporationLNG

Dane bibliometryczne

ID BaDAP150282
Data dodania do BaDAP2023-12-02
Tekst źródłowyURL
DOI10.3390/en16227666
Rok publikacji2023
Typ publikacjiartykuł w czasopiśmie
Otwarty dostęptak
Creative Commons
Czasopismo/seriaEnergies

Abstract

At least 24 liquefied natural gas (LNG) rollover incidents have been reported since 1960. During rollover, because of the heat ingress through the tank walls, a stratified LNG may be suddenly homogenized while releasing massive amounts of vapor. It can result in an overpressure in the tank and significant amounts of potentially explosive LNG vapor being vented out. Both of these factors represent considerable hazards. Rollover is a physical mixing process in a single tank with two or more different cells of LNG of different compositions, temperatures, and densities that can manifest in large boil-off rates. It can exceed venting equipment capacities, and vapor pressure in tank increases rapidly and in extreme cases can lead to tank damage. This paper presents numerical approach for determination of time of rollover occurrence in storage tank. The presented model is based on the energy balance of the stratified cryogenic liquid and the gas phase as separate three thermodynamic systems in the storage tank. As a result of proposed model, for the adopted assumptions and cylindrical tank volume of 78,500 m3, the approximate time of the rollover occurrence was determined for two cases. In the first case, for heavier LNG, the rollover phenomenon will occur 193.25 h after the start of the calculations from the assumed initial conditions. In the second case, for light LNG with a higher initial liquid level in the tank, the rollover will occur after 150.25 h.

Publikacje, które mogą Cię zainteresować

fragment książki
Prediction of boil off rate in liquefied natural gas storage processes / Tomasz WŁODEK // W: SGEM 2017 : 17th international multidisciplinary scientific geoconference : 27-29 November, 2017, Vienna, Austria : conference proceedings. Vol. 17, Science and technologies in geology, exploration and mining. Iss. 15, Oil and gas exploration. — Sofia : STEF92 Technology Ltd., cop. 2017. — (International Multidisciplinary Scientific GeoConference SGEM ; ISSN 1314-2704). — ISBN: 978-619-7408-26-3. — S. 405–413. — Bibliogr. s. 412–413, Abstr.
artykuł
Liquefied natural gas storage of variable composition — Magazynowanie skroplonego gazu ziemnego o zmiennym składzie / Mariusz ŁACIAK // Archives of Mining Sciences = Archiwum Górnictwa ; ISSN 0860-7001. — 2015 — vol. 60 no. 1, s. 225–238. — Bibliogr. s. 238