Efficiency of a compressor heat pump system in different cycle designs: a simulation study for low-enthalpy geothermal resources / Jakub SZYMICZEK, Krzysztof SZCZOTKA, Marian BANAŚ, Przemysław Jura // Energies [Dokument elektroniczny]. — Czasopismo elektroniczne ; ISSN 1996-1073. — 2022 — vol. 15 iss. 15 art. no. 5546, s. 1–19. — Wymagania systemowe: Adobe Reader. — Bibliogr. s. 16–19, Abstr. — Publikacja dostępna online od: 2022-07-30

Autorzy (4)

Słowa kluczowe

Ebsilonrenewable energy sourcesheat pumplow enthalpy geothermalthermodynamic cycle designCOPgeothermal energy

Dane bibliometryczne

ID BaDAP141666
Data dodania do BaDAP2022-08-31
Tekst źródłowyURL
DOI10.3390/en15155546
Rok publikacji2022
Typ publikacjiartykuł w czasopiśmie
Otwarty dostęptak
Creative Commons
Czasopismo/seriaEnergies

Abstract

The development of district heating systems results in a search for alternative heat sources. One of these is low-enthalpy geothermic energy, more available than traditional geothermal energy. However, utilization of these resources is difficult, due to the low quality of the produced heat. To utilize them, the heat pump system can be used. Such a system was designed for this case study of a city in a region of the Polish Lowlands. The data necessary for the design came from the project of the borehole and operational parameters of the existing heating plant. Four heat pump-cycle designs were proposed, modeled, and simulated using Ebsilon software. Afterward, the designs were optimized to achieve maximum coefficient of performance (COP) value. As a result of the simulation, the efficiency of each design was determined and the seasonal COP value was calculated with the annual measured heat demand of the plant. The system based on the cascade design proved the most efficient, with a seasonal COP of 7.19. The seasonal COP for the remaining basic, subcooling, and regenerator variants was 5.61, 3.73, and 5.60, respectively. The annual heat production of the designed system (22,196 MWh) was calculated based on the thermal power of the designed system and historical demand data. This paper presents a simulation methodology for assessment of the efficiency and feasibility of a heat pump system in district heating.

Publikacje, które mogą Cię zainteresować

artykuł
#130410Data dodania: 2.10.2020
Low enthalpy geothermal resources for local sustainable development: a case study in Poland / Aleksandra SZULC-WROŃSKA, Barbara TOMASZEWSKA // Energies [Dokument elektroniczny]. — Czasopismo elektroniczne ; ISSN 1996-1073. — 2020 — vol. 13 iss. 19 art. no. 5010, s. 1-20. — Wymagania systemowe: Adobe Reader. — Bibliogr. s. 16-20, Abstr. — Publikacja dostępna online od: 2020-09-23
artykuł
#137768Data dodania: 26.11.2021
Innovative desalination of geothermal wastewater supported by electricity generated from low-enthalpy geothermal resources / Michał KACZMARCZYK, Barbara TOMASZEWSKA, Wiesław Bujakowski // Desalination ; ISSN 0011-9164. — 2022 — vol. 524 art. no. 115450, s. 1–13. — Bibliogr. s. 12–13, Abstr. — Publikacja dostępna online od: 2021-11-22. — B. Tomaszewska - dod. afiliacja: Mineral and Energy Economy Research Institute, Polish Academy of Sciences, Kraków