Impact of air density variation on a simulated earth-to-air heat exchanger’s performance / Piotr MICHALAK // Energies [Dokument elektroniczny]. — Czasopismo elektroniczne ; ISSN 1996-1073. — 2022 — vol. 15 iss. 9 art. no. 3215, s. 1-24. — Wymagania systemowe: Adobe Reader. — Bibliogr. s. 21-24, Abstr. — Publikacja dostępna online od: 2022-04-27

Autor

Słowa kluczowe

barometric formulaEAHEearth-to-air heat exchangerair densityground temperatureoutlet temperaturehourly simulationEN ISO 13790specific heat of air5R1C model

Dane bibliometryczne

ID BaDAP140020
Data dodania do BaDAP2022-04-29
Tekst źródłowyURL
DOI10.3390/en15093215
Rok publikacji2022
Typ publikacjiartykuł w czasopiśmie
Otwarty dostęptak
Creative Commons
Czasopismo/seriaEnergies

Abstract

Due to their simple design and reliable operation, earth-to-air heat exchangers (EAHE) are used in modern buildings to reduce ventilation heat losses. EAHE operation in atmospheric conditions results in variation in ambient air temperature and pressure affecting air density. The paper presents the study on the impact of ambient air density variation on the calculated hourly air temperature at the EAHE outlet and the resulting energy use for space heating and cooling of an exemplary residential building. The ground temperature was computed from the model given in EN 16798-5-1. Then, air density was obtained using five various methods. Energy use for space heating and cooling of the building was computed using the 5R1C thermal network model of EN ISO 13790. Depending on the chosen method and concerning the base case without EAHE,a reduction in annual heating and cooling needs was obtained from 7.5% to 8.8% in heating and from 15.3% to 19% in cooling. Annual heating and cooling gain from EAHE were 600.9 kWh and 628.3 kWh for heating and 616.9 kWh and 603.5 kWh forcooling for the Typical Meteorological Years (TMY) and International Weather for Energy Calculation (IWEC) files, respectively. Unit heating and cooling gains per heat exchanger area were from 34.9 kWh/m2 to 36.8 kWh/m2 and from −35.1 kWh/m2 to −36.3 kWh/m2. Density variation with temperature from the relevant typical Polish meteorological year at constant pressure, in comparison to the method of EN 16798-5-1, resulted in an hourly difference of that unit gain up to 4.3 W/m2 and 2.0 W/m2 for heating and cooling, respectively. The same was true inthe case of IWEC files that resulted in differences of 5.5 W/m2 and 1.1 W/m2.

Publikacje, które mogą Cię zainteresować

artykuł
#139413Data dodania: 8.3.2022
Hourly simulation of an earth-to-air heat exchanger in a low-energy residential building / Piotr MICHALAK // Energies [Dokument elektroniczny]. — Czasopismo elektroniczne ; ISSN 1996-1073. — 2022 — vol. 15 iss. 5 art. no. 1898, s. 1–23. — Wymagania systemowe: Adobe Reader. — Bibliogr. s. 19–23, Abstr. — Publikacja dostępna online od: 2022-03-04
artykuł
#129730Data dodania: 3.9.2020
Ventilation heat loss in a multifamily building under varying air density / Piotr MICHALAK // Journal of Mechanical and Energy Engineering ; ISSN 2544-0780. — 2020 — vol. 4 no. 1, s. 97–101. — Bibliogr. s. 100–101, Abstr. — Publikacja dostępna online od: 2020-08-09