Szczegóły publikacji

Opis bibliograficzny

The performance and long-time stability of potentiometric ${CO_{2}}$ gas sensors based on the ${(Li-Ba)CO_{3}\mid NASICON\mid (Na-Ti-O)}$ electrochemical cells / P. PASIERB, S. KOMORNICKI, R. GAJERSKI, S. KOZIŃSKI, M. RĘKAS // Solid State Ionics ; ISSN 0167-2738. — 2003 — vol. 157 iss. 1-4 art. no. PII S0167-2738(02)00233-3, s. 357–363. — Bibliogr. s. 362–363, Abstr. — 6th International Symposium on Systems with Fast Ionic Transport (ISSFIT) : Krakow, Poland, May 9–12, 2001

Autorzy (5)

Słowa kluczowe

nasiconsensor stabilitysolid electrolyteselectrochemical gas sensorscarbon dioxidecarbonates

Dane bibliometryczne

ID BaDAP13813
Data dodania do BaDAP2003-07-24
DOI10.1016/S0167-2738(02)00233-3
Rok publikacji2003
Typ publikacjireferat w czasopiśmie
Otwarty dostęptak
Czasopismo/seriaSolid State Ionics

Abstract

Solid-state potentiometric CO2 sensors were fabricated using Na+ conductor (Na3Zr2Si2PO12) as a solid electrolyte, Li2CO3-BaCO3 fused carbonate with different compositions as a sensing electrode and the Na2Ti6O13-Na2Ti3O7 or TiO2-Na2Ti6O13 two phase systems as a reference electrode. The measured electromotive force of the investigated cells was found to be linear with the logarithm Of CO2 partial pressure in the range 100-12 600 ppm of CO2 and in the temperature range 300-500 degreesC. The response time was ca. 40-120 s. The sensors exhibited reproducible signal during short-time experiments (<24 h). However, the unstable behaviour was observed during long-time measurements (several weeks) in case of some sensors, and it was found to be sensor composition dependent. A sensing mechanism is proposed on the basis of the sensing characteristics obtained. The possible explanation of the observed long-time instability of investigated sensors is also given. (C) 2002 Elsevier Science B.V. All rights reserved.

Publikacje, które mogą Cię zainteresować

artykuł
#17319Data dodania: 17.9.2004
Long-term stability of potentiometric $CO_{2}$ sensors based on Nasicon as a solid electrolyte / P. PASIERB, S. KOMORNICKI, S. KOZIŃSKI, R. GAJERSKI, M. RĘKAS // Sensors and Actuators. B, Chemical ; ISSN 0925-4005. — 2004 — vol. 101 iss. 1–2, s. 47–56. — Bibliogr. s. 56, Abstr.
artykuł
#69672Data dodania: 10.12.2012
Application of anion-conducting lanthanum oxychloride for potentiometric chlorine gas sensors / Małgorzata DZIUBANIUK, Małgorzata Trzęsiec, Paweł PASIERB, Mieczysław RĘKAS // Solid State Ionics ; ISSN 0167-2738. — 2012 — vol. 225, s. 324–327. — Bibliogr. s. 327, Abstr. — Solid State Ionics 18 : proceedings of the 18th International Conference on Solid State Ionics (SSI-18) : Warsaw, Poland, July 3–8, 2011 / eds. F. Krok [et al.]