Planar single and dual-resonant microwave biosensors for label-free bacteria detection / Ilona PIEKARZ, Sabina Górska, Agnieszka Razim, Jakub SOROCKI, Krzysztof WINCZA, Marek Drab, Sławomir GRUSZCZYŃSKI // Sensors and Actuators. B, Chemical ; ISSN 0925-4005. — 2022 — vol. 351 art. no. 130899, s. 1-10. — Bibliogr. s. 9, Abstr. — Publikacja dostępna online od: 2021-10-09

Autorzy (7)

Słowa kluczowe

microwave sensorsmulti-resonatorbacteria detectionmicrowave resonatorbiosensorslabel-free sensorsdifferential excitation

Dane bibliometryczne

ID BaDAP137420
Data dodania do BaDAP2021-11-09
Tekst źródłowyURL
DOI10.1016/j.snb.2021.130899
Rok publikacji2022
Typ publikacjiartykuł w czasopiśmie
Otwarty dostęptak
Creative Commons
Czasopismo/seriaSensors and Actuators, B, Chemical

Abstract

Label-free microwave resonator-type biosensors covered with polyclonal anti-Escherichia coli antibodies are presented. The sensors` construction provides high sensitivity on the bacteria detection, whereas the utilization of specific antibodies ensures selective bacteria binding. Two types of biosensors are studied to explore the benefits of microwave sensing: the first one, in which increased sensitivity on the bacteria detection is obtained due to the differential excitation of the resonating conductors, and the second one, in which a multi-resonant character increases the probability for the bacteria detection. The exemplary sensors were designed to operate in the frequency range of 4.4 – 4.8 GHz or 15 – 25 GHz and physically realized on a silicon wafer using standard microelectronic processor using the United Monolithic Semiconductor (UMS) PH25 process on a 100 µm thick GaAs substrate, respectively. The sensors were experimentally validated by measurements of various concentrations of Escherichia coli. Both types of sensors were compared to show their advantages and disadvantages in terms of future use for biomedical applications. Both biosensors were shown to enable bacteria detection at concentrations reaching as low as 103 CFU/ml. Interestingly, a monotonic response for bacteria concentration was observed for a multi-resonant sensor, which can be utilized for estimation of bacteria content using the calibration curve.

Publikacje, które mogą Cię zainteresować

fragment książki
#151823Data dodania: 20.3.2024
Microwave biosensors for label-free bacteria detection / Ilona PIEKARZ, Jakub SOROCKI, Sabina Gorska, Krzysztof WINCZA, Sławomir GRUSZCZYŃSKI // W: IMBioC 2023 [Dokument elektroniczny] : 2023 IEEE MTT-S International Microwave Biomedical Conference : 11–13 September 2023, Leuven, Belgium. — Wersja do Windows. — Dane tekstowe. — [Piscataway : IEEE], [2023]. — Dod. ISBN: 978-1-6654-9218-8. — e-ISBN: 978-1-6654-9217-1. — S. 109–111. — Wymagania systemowe: Adobe Reader. — Bibliogr. s. 111, Abstr. — Publikacja dostępna online od: 2023-11-07
artykuł
#125618Data dodania: 21.1.2020
A microwave matrix sensor for multipoint label-free Escherichia coli detection / Ilona PIEKARZ, Sabina Górska, Szczepan ODROBINA, Marek Drab, Krzysztof WINCZA, Andrzej Gamian, Sławomir GRUSZCZYŃSKI // Biosensors and Bioelectronics ; ISSN 0956-5663. — 2020 — vol. 147 art. no. 111784, s. 1–6. — Bibliogr. s. 6, Abstr. — Publikacja dostępna online od: 2019-10-12