Experimental and theoretical study on the internal convective and radiative heat transfer coefficients for a vertical wall in a residential building / Piotr MICHALAK // Energies [Dokument elektroniczny]. — Czasopismo elektroniczne ; ISSN 1996-1073. — 2021 — vol. 14 iss. 18 art. no. 5953, s. 1-22. — Wymagania systemowe: Adobe Reader. — Bibliogr. s. 19-22, Abstr. — Publikacja dostępna online od: 2021-09-19

Autor

Słowa kluczowe

radiationcorrelationconvectionheat transfer coefficient

Dane bibliometryczne

ID BaDAP136282
Data dodania do BaDAP2021-09-30
Tekst źródłowyURL
DOI10.3390/en14185953
Rok publikacji2021
Typ publikacjiartykuł w czasopiśmie
Otwarty dostęptak
Creative Commons
Czasopismo/seriaEnergies

Abstract

Experimental studies on internal convective (CHTC) and radiative (RHTC) heat transfer coefficients are very rarely conducted in real conditions during the normal use of buildings. This study presents the results of measurements of CHTC and RHTC for a vertical wall, taken in a selected room of a single-family building during its everyday use. Measurements were performed using HFP01 heat flux plates, Pt1000 sensors for internal air and wall surface temperatures and a globe thermometer for mean radiant temperature measured in 10 min intervals. Measured average CHTC and RHTC amounted to 1.15 W/m2K and 5.45 W/m2K, compared to the 2.50 W/m2K and 5.42 W/m2K recommended by the EN ISO 6946, respectively. To compare with calculated CHTC, 14 correlations based on the temperature difference were applied. Obtained values were from 1.31 W/m2K (given by Min et al.,) to 3.33 W/m2K (Wilkes and Peterson), and in all cases were greater than the 1.15 W/m2K from measurements. The average value from all models amounted to 2.02 W/m2K, and was greater than measurements by 75.6%. The quality of models was also estimated using average absolute error (AAE), average biased error (ABE), mean absolute error (MAE) and mean bias error (MBE). Based on these techniques, the model of Fohanno and Polidori was identified as the best with AAE = 68%, ABE = 52%, MAE = 0.41 W/m2K and MBE = 0.12 W/m2K.

Publikacje, które mogą Cię zainteresować

artykuł
#159042Data dodania: 6.5.2025
Experimental study on heat transfer coefficients in an office room with a radiant ceiling during low heating loads / Piotr MICHALAK // Energies [Dokument elektroniczny]. — Czasopismo elektroniczne ; ISSN  1996-1073 . — 2025 — vol. 18 iss. 7 art. no. 1591, s. 1–19. — Wymagania systemowe: Adobe Reader. — Bibliogr. s. 17–19, Abstr. — Publikacja dostępna online od: 2025-03-22
artykuł
#45774Data dodania: 6.7.2009
Experimental study on the magnetic convection in a vertical cylinder / Elżbieta FORNALIK, Piotr Filar, Toshio Tagawa, Hiroyuki Ozoe, Janusz S. SZMYD // Experimental Thermal and Fluid Science ; ISSN 0894-1777. — 2005 — vol. 29 iss. 8, s. 971–980. — Bibliogr. s. 980, Abstr.