Performance evaluation of a single-stage two-bed adsorption chiller with desalination function / Karol SZTEKLER, Wojciech KALAWA, Wojciech NOWAK, Łukasz MIKA, Jarosław Krzywański, Karolina Grabowska, Marcin Sosnowski, Ahmed A. Alharbi // Journal of Energy Resources Technology ; ISSN 0195-0738. — 2021 — vol. 143 iss. 8 art. no. 082101, s. 082101-1–082101-7. — Bibliogr. s. 082101-7. — Publikacja dostępna online od: 2020-11-04

Autorzy (8)

Słowa kluczowe

energy systemsalternative energy sourcesrenewable energyenergy conversion

Dane bibliometryczne

ID BaDAP130968
Data dodania do BaDAP2020-11-09
DOI10.1115/1.4048771
Rok publikacji2021
Typ publikacjiartykuł w czasopiśmie
Otwarty dostęptak
Czasopismo/seriaJournal of Energy Resources Technology-Transactions of the ASME

Abstract

Energy efficiency is one of the most important topics nowadays. It is strictly related to the problem of energy demand, energy policy, environmental pollution, and economic issues. Because of the technological development, using more advanced processes in almost every part of industry and increasing demands both for a high standard of living and simplification of processes, the energy demand is growing. This can be observed, e.g., in the building sector—air conditioning is present in almost every new building and people expect high quality thermal conditions. At the same time, many technological processes result in dissipating energy to the environment. Energy efficiency can be increased and operation costs reduced by using waste heat in other processes. One of the possibilities is to use sorption chillers to produce cool and desalinated water. Low temperature waste heat is not easy to utilize because of low energy potential. Using adsorption chillers in low temperature conditions allows utilizing waste heat and producing useful products in many regions of the world. The paper presents the results of experimental study carried out on three-bed adsorption chiller with desalination, using silica gel and water as the working pair. The chiller was equipped with plate-fin tube heat exchanger filled with silica gel with a grain size of 0.5–1.5 mm. The laboratory test stand included one evaporator, one condenser, and three separate tanks for water, desalinated water, and brine, respectively. The test stand scheme and description were presented. All results were obtained during a few hours test with stable temperature conditions in the range of 55–85 °C for the heating water.

Publikacje, które mogą Cię zainteresować

artykuł
#151395Data dodania: 22.2.2024
Conceptual design of experimental test rig for research on thermo-flow processes during direct contact condensation in the two-phase spray-ejector condenser / Paweł MADEJSKI, Michał KARCH, Piotr MICHALAK, Krzysztof Banasiak // Journal of Energy Resources Technology ; ISSN 0195-0738. — 2024 — vol. 146 iss. 3 art. no. 030902, s. 030902-1–030902-12. — Bibliogr. s. 030902-11–030902-12, Abstr. — Publikacja dostępna online od: 2024-01-09
artykuł
#127871Data dodania: 20.3.2020
Industrial process description for the recovery of agricultural water from digestate / Halina Pawlak-Kruczek, Agnieszka Urbanowska, Weihong Yang, Gerrit Brem, Aneta MAGDZIARZ, Przemysław Seruga, Łukasz Niedźwiecki, Artur Pozarlik, Agata MLONKA-MĘDRALA, Małgorzata Kabsch-Korbutowicz, Eduard A. Bramer, Marcin Baranowski, Małgorzata SIERADZKA, Monika Tkaczuk-Serafin // Journal of Energy Resources Technology ; ISSN 0195-0738. — 2020 — vol. 142 iss. 7 art. no. 070917, s. 075001-1–075001-8. — Bibliogr. s. 075001-7–075001-8. — Publikacja dostępna online od: 2020-02-28. — 44th International Technical Conference on Clearwater Clean Energy : Clearwater, June 16–21, 2019