Szczegóły publikacji

Opis bibliograficzny

The Mn‐zeolite/graphite modified glassy carbon electrode: fabrication, characterization and analytical applications / Radosław PORADA, Katarzyna FENDRYCH, Bogusław BAŚ // Electroanalysis [Dokument elektroniczny]. — Czasopismo elektroniczne ; ISSN 1521-4109. — 2020 — vol. 32 iss. 6, s. 1208–1219. — Wymagania systemowe: Adobe Reader. — Bibliogr. s. 1218-1219, Abstr. — Publikacja dostępna online od: 2020-01-27

Autorzy (3)

Słowa kluczowe

electrochemical sensorparacetamolzeolitevoltammetrypharmaceuticals

Dane bibliometryczne

ID BaDAP128956
Data dodania do BaDAP2020-06-16
Tekst źródłowyURL
DOI10.1002/elan.201900744
Rok publikacji2020
Typ publikacjiartykuł w czasopiśmie
Otwarty dostęptak
Czasopismo/seriaElectroanalysis

Abstract

n this work, low‐cost and environmentally friendly natural zeolite exchanged with Mn2+ cations was used for the first time to modify the glassy carbon electrode with the aim to obtain a fast and simple sensor for voltammetric determination of paracetamol (PAR). The Mn‐zeolite/graphite modified glassy carbon electrode (MnZG−GCE) was prepared by evaporation of solvent from dispersion of the zeolite/graphite mixture with the polymer in acetone. The electrochemical characteristics of MnZG−GCE were conducted by electrochemical impedance spectroscopy and cyclic voltammetry. Compared with graphite modified GCE (G−GCE), MnZG−GCE exhibited better electrochemical parameters, which confirms the superiority of applying zeolite in the proposed sensor. The optimization of the pH‐value of supporting electrolyte and instrumental parameters were carried out. The peak current was proportional to the concentration of PAR in a phosphate buffer saline of pH 6.0 in the range from 0.029 to 0.69 mg L−1 (R=0.9997) with limit of detection of 8.8 μg L−1. Finally, the proposed electrode was successfully applied to determine the paracetamol in pharmaceutical formulation and certified reference materials. The satisfactory recoveries, which ranged from 89.2 to 102.7 %, were obtained for all studied samples. It confirmed the attractiveness of relatively inexpensive, easy to fabricate and non‐toxic MnZG−GCE in determination of PAR in complicated matrixes.

Publikacje, które mogą Cię zainteresować

artykuł
#133992Data dodania: 7.5.2021
Development of novel Mn-zeolite/graphite modified Screen-printed Carbon Electrode for ultrasensitive and selective determination of folic acid / Radosław PORADA, Katarzyna FENDRYCH, Bogusław BAŚ // Measurement ; ISSN 0263-2241. — 2021 — vol. 179 art. no. 109450, s. 1–11. — Bibliogr. s. 10–11, Abstr. — Publikacja dostępna online od: 2021-04-24
artykuł
#131113Data dodania: 25.11.2020
Application of Fe(III)-exchanged clinoptilolite/graphite nanocomposite for electrochemical sensing of amitriptyline / Maria Madej, Katarzyna FENDRYCH, Radosław PORADA, Mateusz Flacha, Jolanta Kochana, Bogusław BAŚ // Microchemical Journal ; ISSN 0026-265X. — 2021 — vol. 160 Pt. A art. no. 105648, s. 1–11. — Bibliogr. s. 9–11, Abstr. — Publikacja dostępna online od: 2020-10-20