Two-point frequency shift method for shear wave attenuation measurement / Piotr KIJANKA, Matthew W. Urban // IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control ; ISSN 0885-3010. — 2020 — vol. 67 no. 3, s. 483–496. — Bibliogr. s. 495–496, Abstr. — Publikacja dostępna online od: 2019-10-04. — P. Kijanka – dod. afiliacja: Mayo Clinic College of Medicine and Science, Rochester, USA

Autorzy (2)

Słowa kluczowe

AMUSEultrasoundphantomviscoelasticSWEattenuationfull-width at half-maximumFWHMacoustic radiation forceattenuation measuring ultrasound shear wave elastographyARFFSfrequency shiftshear wave elastographysoft tissue

Dane bibliometryczne

ID BaDAP128097
Data dodania do BaDAP2020-04-01
Tekst źródłowyURL
DOI10.1109/TUFFC.2019.2945620
Rok publikacji2020
Typ publikacjiartykuł w czasopiśmie
Otwarty dostęptak
Czasopismo/seriaIEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control

Abstract

Ultrasound shear wave elastography (SWE) is an increasingly used noninvasive modality for quantitative evaluation of tissue mechanical properties. SWE typically uses an acoustic radiation force to produce laterally propagating shear waves that are tracked in the spatial and temporal domains, in order to obtain the wave velocity. One of the ways to study the viscoelasticity is through studying the shear wave phase velocity dispersion curves. Shear wave attenuation can be also characterized in viscoelastic tissues with methods that use multiple lateral data samples. In this article, we present an alternative method for measuring the shear wave attenuation without using a rheological model two-point frequency shift (2P-FS). The technique uses information related to the amplitude spectra FS of shear waves measured at only two lateral locations. The theoretical basis for the 2P-FS is derived and validated. We examined how the first signal position and the distance between the two locations affect the shear wave attenuation estimation in the 2P-FS method. We tested this new method on digital phantom data created using the local interaction simulation approach (LISA) in viscoelastic media. Moreover, we tested data acquired from custom-made tissue-mimicking viscoelastic phantom experiments and ex vivo porcine liver measurements. We compared results from the 2P-FS method with the other two techniques used for assessing a shear wave attenuation: the FS-based method and the attenuation-measuring ultrasound shear wave elastography (AMUSE) technique. In addition, we evaluated the 2P-FS algorithm with different levels of added white Gaussian noise to the shear wave particle velocity using numerical phantoms. Tests conducted showed that the 2P-FS method gives robust results based on only two measurements and can be used to measure attenuation of viscoelastic soft tissues.

Publikacje, które mogą Cię zainteresować

artykuł
#139776Data dodania: 14.4.2022
Improved two-point frequency shift power method for measurement of shear wave attenuation / Piotr KIJANKA, Matthew W. Urban // Ultrasonics ; ISSN 0041-624X. — 2022 — vol. 124 art. no. 106735, s. 1-16. — Bibliogr. s. 15-16, Abstr. — Publikacja dostępna online od: 2022-03-29
artykuł
#128098Data dodania: 1.4.2020
Fast local phase velocity-based imaging: shear wave particle velocity and displacement motion study / Piotr KIJANKA, Matthew W. Urban // IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control ; ISSN 0885-3010. — 2020 — vol. 67 no. 3, s. 526–537. — Bibliogr. s. 536–537, Abstr. — Publikacja dostępna online od: 2019-10-21. — P. Kijanka – dod. afiliacja: Mayo Clinic College of Medicine and Science, Rochester, USA