Szczegóły publikacji

Opis bibliograficzny

Continuous distant measurement of the user's heart rate in human-computer interaction applications / Jaromir PRZYBYŁO // Sensors [Dokument elektroniczny]. — Czasopismo elektroniczne ; ISSN 1424-8220. — 2019 — vol. 19 iss. 19 art. no. 4205, s. 1–22. — Wymagania systemowe: Adobe Reader. — Bibliogr. s. 20–22, Abstr. — Publikacja dostępna online od: 2019-09-27

Autor

Słowa kluczowe

image processinghuman computer interactionassisted livinghealthcarevideo pletysmographyheart rate estimationbiomedicine

Dane bibliometryczne

ID BaDAP124960
Data dodania do BaDAP2019-10-14
Tekst źródłowyURL
DOI10.3390/s19194205
Rok publikacji2019
Typ publikacjiartykuł w czasopiśmie
Otwarty dostęptak
Creative Commons
Czasopismo/seriaSensors

Abstract

In real world scenarios, the task of estimating heart rate (HR) using video plethysmography (VPG) methods is difficult because many factors could contaminate the pulse signal (i.e., a subjects’ movement, illumination changes). This article presents the evaluation of a VPG system designed for continuous monitoring of the user’s heart rate during typical human-computer interaction scenarios. The impact of human activities while working at the computer (i.e., reading and writing text, playing a game) on the accuracy of HR VPG measurements was examined. Three commonly used signal extraction methods were evaluated: green (G), green-red difference (GRD), blind source separation (ICA). A new method based on an excess green (ExG) image representation was proposed. Three algorithms for estimating pulse rate were used: power spectral density (PSD), autoregressive modeling (AR) and time domain analysis (TIME). In summary, depending on the scenario being studied, different combinations of signal extraction methods and the pulse estimation algorithm ensure optimal heart rate detection results. The best results were obtained for the ICA method: average RMSE = 6.1 bpm (beats per minute). The proposed ExG signal representation outperforms other methods except ICA (RMSE = 11.2 bpm compared to 14.4 bpm for G and 13.0 bmp for GRD). ExG also is the best method in terms of proposed success rate metric (sRate).

Publikacje, które mogą Cię zainteresować

artykuł
#60291Data dodania: 25.7.2011
Wearable wireless heart rate monitor for continuous long-term variability studies / Piotr AUGUSTYNIAK // Journal of Electrocardiology ; ISSN 0022-0736. — 2011 — vol. 44 no. 2, s. 195–200. — Bibliogr. s. 200, Abstr. — The 37th International Congress on Electrocardiology (ICE), Lund, Sweden, [June 3–5, 2010]. — New York : Elsevier, [2011]
artykuł
#60065Data dodania: 8.7.2011
Personal wearable monitor of the heart rate variability / Piotr AUGUSTYNIAK // Bio-Algorithms and Med-Systems / Jagiellonian University. Medical College ; ISSN 1895-9091. — 2011 — vol. 7 no. 1, s. 5–10. — Bibliogr. s. 9, Abstr.