Szczegóły publikacji

Opis bibliograficzny

Energy performance of a low-cost PhotoVoltaic/Thermal (PVT) collector with and without thermal insulation / F. Calise, R. D. Figaj, L. Vanoli // IOP Conference Series: Earth and Environmental Science ; ISSN 1755-1307. — 2019 — vol. 214 art. no. 012116, s. 1–12. — Wymagania systemowe: Adobe Reader. — Bibliogr. s. 11–12, Abstr. — R. D. Figaj – afiliacja: University of Naples Parthenope. — International Conference on the Sustainable Energy and Environmental Development : 14–17 November 2017, Krakow, Poland

Autorzy (3)

  • Calise Francesco
  • Figaj Rafał Damian
  • Vanoli Laura

Dane bibliometryczne

ID BaDAP124887
Data dodania do BaDAP2019-10-10
Tekst źródłowyURL
DOI10.1088/1755-1315/214/1/012116
Rok publikacji2019
Typ publikacjireferat w czasopiśmie
Otwarty dostęptak
Creative Commons
Czasopismo/seriaIOP Conference Series: Earth and Environmental Science

Abstract

In this paper the performance analysis of a low cost/tech PhotoVoltaic/Thermal (PVT) solar collector is presented. The unit under investigation consists of a commercially available flat-plate hybrid unit, based on the use of a polycrystalline PV module and a roll-bond aluminium absorber. The unit is not equipped with any back/frame insulation and glass cover/air layer. A one-dimensional finite-volume model is developed in order to analyse the collector performance. The computational domain is discretized along the longitudinal flow direction of the collector, and mass and energy balance equations are used. This paper is based on a previous work, where the standard PVT collector configuration, without any back insulation, is experimentally and numerically analysed. Here, a possible integration of back insulation layer is analysed numerically considering different insulation materials and thicknesses. In particular, the available experimental data is used in order to simulate the operation of the collector with different back insulation configurations. A comparison between standard and insulated configurations is performed. The performance is also analysed along the discretization direction for all considered configurations. Finally, a sensitivity analysis is performed in order to compare the performance of the several collector configurations as a function of the main design/operation parameters.

Publikacje, które mogą Cię zainteresować

fragment książki
#124904Data dodania: 10.10.2019
Exergy performance of a low-tech PhotoVoltaic/Thermal (PVT) collector with and without thermal insulation / Francesco Calise, Rafał Damian FIGAJ, Laura Vanoli // W: ThermaComp 2018 [Dokument elektroniczny] : fifth international conference on Computational methods for thermal problems : July 9–11, 2018, Bangalore, India / eds. Nicola Massarotti, [et al.]. — Wersja do Windows. — Dane tekstowe. — [India : Indian Institute of Science], cop. 2018. — (International Conference on Computational Methods for Thermal Problems ; ISSN 2305-6924). — S. 452–455. — Wymagania systemowe: Adobe Reader. — Tryb dostępu: http://www.thermacomp.com/uploads/Proceedings_ThermaComp2018.pdf [2019-10-02]. — Bibliogr. s. 455. — R. D. Figaj – afiliacja: University of Naples Parthenope
artykuł
#119776Data dodania: 12.2.2019
Energy performance of the photovoltaic system in urban area – case study / M. ŻOŁĄDEK, M. FILIPOWICZ, K. SORNEK, R. D. FIGAJ // IOP Conference Series: Earth and Environmental Science ; ISSN 1755-1307. — 2019 — vol. 214 [no.] 1 art. no. 012123, s. 1–10. — Bibliogr. s. 10, Abstr. — Publikacja dostępna online od: 2019-01-24. — 2nd International conference on the Sustainable energy and environmental development : 14–17 November 2017, Krakow, Poland