Szczegóły publikacji
Opis bibliograficzny
Nonlinear optimal-based vibration control for systems with MR tuned vibration absorbers / Paweł MARTYNOWICZ // Journal of Low Frequency Noise Vibration and Active Control ; ISSN 1461-3484. — 2019 — vol. 38 iss. 3–4, s. 1607–1628. — Bibliogr. s. 1626–1628, Abstr. — Publikacja dostępna online od: 2019-01-10
Autor
Słowa kluczowe
Dane bibliometryczne
| ID BaDAP | 124652 |
|---|---|
| Data dodania do BaDAP | 2019-10-09 |
| Tekst źródłowy | URL |
| DOI | 10.1177/1461348418819410 |
| Rok publikacji | 2019 |
| Typ publikacji | artykuł w czasopiśmie |
| Otwarty dostęp | |
| Creative Commons | |
| Czasopismo/seria | Journal of Low Frequency Noise Vibration and Active Control |
Abstract
In this paper, the author proposes several approaches to nonlinear optimal-based control implementation. The vibrating system (structure) equipped with two tuned vibration absorbers (TVAs) is analysed against a system with one TVA. For control purposes, MR dampers are used instead of TVAs' passive viscous dampers. The main contribution of this research is the development and numerical verification of three nonlinear optimal-based vibration control concepts (the implementation of one-step optimal control, quasi-optimal control, and the optimal-based modified ground-hook law) that produce MR damper required current (not required force) as their output (thus force tracking algorithm that results in control inaccuracy is entirely omitted here), and that may be directly applicable for online and real-time control; moreover, all of the MR damper force constraints (no active forces; lower and upper limits; nonlinear, hysteresis-type dynamics) are embedded in the control technique, thus the solution is optimal for the assumed actuator respecting its limitations. The proposed approaches are investigated against the standard ground-hook law and passive TVA(s) with optimally tuned (i.e. having a frequency response maxima of equal and lowest values) parameters. The performance of all the solutions for the one- and two-TVA systems is compared, confirming the validity and efficiency of the three proposed concepts: almost 50% reduction of the Dynamic Amplification Factor is possible with regard to the respective optimally tuned passive 1 TVA and 2 TVA configurations. No offline calculation, excitations/disturbances assumption, or frequency determination is necessary. © The Author(s) 2019.