Szczegóły publikacji
Opis bibliograficzny
Preliminary assessment of the local solar energy conditions in the health resort of Rabka-Zdrój - as a potential for using photovoltaic micro-installations / Aleksandra SZULC, Barbara TOMASZEWSKA // W: Renewable energy sources: engineering, technology, innovation : ICORES 2018 : [June 20-22, 2018, Krynica, Poland] / eds. Marek Wróbel, Marcin Jewiarz, Andrzej Szlęk. — Cham : Springer Nature Switzerland, 2020. — (Springer Proceedings in Energy ; ISSN 2352-2534). — ISBN: 978-3-030-13887-5; e-ISBN: 978-3-030-13888-2. — S. 667–676. — Bibliogr., Abstr. — Publikacja dostępna online od: 2019-07-17
Autorzy (2)
Słowa kluczowe
Dane bibliometryczne
| ID BaDAP | 123781 |
|---|---|
| Data dodania do BaDAP | 2019-09-09 |
| DOI | 10.1007/978-3-030-13888-2_65 |
| Rok publikacji | 2020 |
| Typ publikacji | materiały konferencyjne (aut.) |
| Otwarty dostęp | |
| Wydawca | Springer |
| Konferencja | 5th International Conference on Renewable Energy Sources |
| Czasopismo/seria | Springer Proceedings in Energy |
Abstract
Rabka-Zdrój is a health resort municipality located in Southern Poland. According to data from the European Commission, the yearly sum of global horizontal irradiation in the health resort of Rabka-Zdrój equals 1100 kWh∙m−2. For this analysis, it was taken into consideration databases from three different sources. It was agreed that the Typical Meteorological Year (TMY) for Kraków city would act as reference data as it was elaborated based on years of observation. This data was compared with PVGIS-CMSAF satellite data as well as with our data received from a ground measurement station (LB-714) located in Rabka-Zdrój. The observations of data from the station LB-714 has shown that 70% of measurements obtained in December falls within the range 0–100 W∙m−2. The results of verification show that differences of distribution of average daily horizontal irradiance are significantly smaller than in the case of an inclined plane at a given angle. The dissimilarity between the PVGIS and TMY data could be a result of the application of the estimated model (for PVGIS) for calculating the values of solar irradiance on the inclined plane and also a reference to another measurement period. Values of total solar irradiance obtained for LB-714 after applying the correction factor, present a similar distribution of values to PVGIS, however, they differ significantly to TMY data. The correction factor for the total solar irradiance on the inclined plane, calculated from TMY data, should be used only for estimated calculations.