Szczegóły publikacji

Opis bibliograficzny

Zjawiska biomineralogiczne w endoprotezach stawu biodrowego — Biomineralogical phenomenon in hip joint endoprostheses / Maciej PAWLIKOWSKI // Auxiliary Sciences in Archaeology, Preservation of Relicts and Environmental Engineering [Dokument elektroniczny]. — Czasopismo elektroniczne = [Nauki Pomocnicze w Archeologii, Konserwacji Zabytków i Inżynierii Środowiska] ; ISSN 1689-6742. — 2018 — no. 25, s. [1–18]. — Wymagania systemowe: Adobe Reader ; napęd CD-ROM. — Bibliogr. s. [16–18], Abstr., Streszcz.

Autor

Słowa kluczowe

EN: ednoprostheseship jointacetabulametal elements
PL: elementy metaloweendoprotezystaw biodrowy

Dane bibliometryczne

ID BaDAP119010
Data dodania do BaDAP2019-01-09
Tekst źródłowyURL
Rok publikacji2018
Typ publikacjiartykuł w czasopiśmie
Otwarty dostęptak
Creative Commons
Czasopismo/seriaAuxiliary Sciences in Archaeology, Preservation of Relicts and Environmental Engineering

Streszczenie

Wykonano badania elementów endoprotez stawu biodrowego pod kątem starzenia się materiałów, rozpoznania struktur stosowanych metali oraz cementów służących do fiksacji endoprotez. Badaniom poddano także „zużyte „ elementy endoprotez po różnych okresach ich funkcjonowania. Stwierdzono, że starzenie się polimerów prowadzi to ich spękania przez co skraca się czas prawidłowego funkcjonowania panewek i całych sztucznych stawów. W „pracujących” elementach metalowych (głowy endoprotez) zaobserwowano w stali wtrącenia mikro żużelków, które po wykruszeniu się ze stali pod czas stawu biodrowego niszczą gładź powierzchni głowy endoptotezy oraz wewnętrzna powierzchnię panewki. Długotrwałe obciążenie panewek prowadzi do zmiany struktury atomowej polipropylenu z którego wykonane są panewki. To pociąga za sobą szybsze niszczenie obciążanej panewki. Badane, dwuskładnikowe cementy fiksujące endoprotezę zawierały banieczki powietrza, co jest efektem mieszania składników. Ich obecność osłabia stabilizacje endoprotezy przyspieszając konieczność jej wymiany.

Abstract

Tests were performed on elements of hip joint endoprostheses regarding aging of the materials, structures of the metals as well as the cements used to fix the implant to the bone.“Worn out” elements of endoprostheses after different periods of functioning were also studied It was determined that aging of the polymers leads to their cracking, which shortens the time of proper functioning of the acetabula and the whole artificial joints. In the “working” metal elements (femoral heads) creation of micro slag bits in the steel was observed. Those bits break out from the steel during the functioning of the hip joint, damaging the surface finishing of the head of the implant and the inner surface of the acetabulum. Long-term load on the acetabula leads to changes in the atomic structure of the polypropylene that they are built of. That causes the acetabula to wear out faster. Two-component fixing cements that were tested contained air bubbles as a result of mixing the components. Their presence weakens the endoprostheses stabilization, accelerating the necessity to replace it.

Publikacje, które mogą Cię zainteresować

artykuł
#119013Data dodania: 9.1.2019
Zjawisko biomineralizacji chrząstki stawu biodrowego — The phenomenon of joint hip cartilage biomineralization / Maciej PAWLIKOWSKI // Auxiliary Sciences in Archaeology, Preservation of Relicts and Environmental Engineering [Dokument elektroniczny]. — Czasopismo elektroniczne = [Nauki Pomocnicze w Archeologii, Konserwacji Zabytków i Inżynierii Środowiska] ; ISSN 1689-6742. — 2018 — no. 25, s. [1–24]. — Wymagania systemowe: Adobe Reader ; napęd CD-ROM. — Bibliogr. s. [22–24], Abstr., Streszcz.
artykuł
#54350Data dodania: 2.11.2010
Przedkliniczne testy endoprotez stawu biodrowego z wykorzystaniem metody elementów skończonych — Preclinical tests of endoprostheses of hip joint using finite element methods / Anna Maria RYNIEWICZ, Tomasz MADEJ // Inżynieria Biomateriałów = Engineering of Biomaterials / Polskie Stowarzyszenie Biomateriałów ; ISSN 1429-7248. — 2010 — R. 13 nr 94, s. 14–23. — Bibliogr. s. 23, Streszcz., Abstr. — Tekst pol.-ang. — A. M. Ryniewicz - dod. afiliacja: Uniwersytet Jagielloński