Szczegóły publikacji

Opis bibliograficzny

Calibration free solid contact electrodes with two PVC based membranes / Bartosz BARTOSZEWICZ, Sylwia DĄBROWSKA, Andrzej LEWENSTAM, Jan MIGDALSKI // Sensors and Actuators. B, Chemical ; ISSN 0925-4005. — 2018 — vol. 274, s. 268–273. — Bibliogr. s. 273, Abstr. — Publikacja dostępna online od: 2018-07-24


Autorzy (4)


Słowa kluczowe

solid contact REFcalibration free ISEsolid contact ISEpotentiometry

Dane bibliometryczne

ID BaDAP115857
Data dodania do BaDAP2018-09-07
Tekst źródłowyURL
DOI10.1016/j.snb.2018.07.111
Rok publikacji2018
Typ publikacjiartykuł w czasopiśmie
Otwarty dostęptak
Czasopismo/seriaSensors and Actuators, B, Chemical

Abstract

A new type of solid contact ion-selective electrodes (ISEs) with two PVC-based sandwiched membranes are described. The first membrane contains suspension of halogen salts of silver and alkaline metals as well as silver nanoparticles and is placed on Ag substrate or conducting substrate covered with silver. It acts as a solid contact of an ion-selective electrode when covered with the second PVC membrane sensitive to potassium, sodium or chloride ions. In this way, the potassium, sodium and chloride electrodes characterized by very stable and reproducible standard potentials and slope were obtained. For example, all tested potassium electrodes with KBr/AgBr based solid contact exhibited E° values equal to: −191.2 ± 1.7 mV and the slope values equal to: −57.1 ± 0.8 mV/pK. Similarly, good results were also obtained for sodium and chloride ISEs. The solid contact offered allows to fabricate so-called “calibration free” ion-sensors.

Publikacje, które mogą Cię zainteresować

artykuł
Development of miniature all-solid-state potentiometric sensing system / Salzitsa Anastasova-Ivanova, Ulriika Mattinen, Aleksander Radu, Johan Bobacka, Andrzej LEWENSTAM, Jan MIGDALSKI, Marek DANIELEWSKI, Dermot Diamond // Sensors and Actuators. B, Chemical ; ISSN 0925-4005. — 2010 — vol. 146 iss. 1, s. 199–205. — Bibliogr. s. 204–205, Abstr. — Andrzej Lewenstam – dod. afiliacja: \AA bo Akademi University
artykuł
Solid-contact electrode with composite PVC-based 3D-printed membrane : optimization of fabrication and performance / Bartosz BARTOSZEWICZ, Andrzej LEWENSTAM, Jan MIGDALSKI // Sensors [Dokument elektroniczny]. — Czasopismo elektroniczne ; ISSN 1424-8220. — 2021 — vol. 21 iss. 14 art. no. 4909, s. 1–11. — Wymagania systemowe: Adobe Reader. — Bibliogr. s. 10–11, Abstr. — Publikacja dostępna online od: 2021-07-19