Szczegóły publikacji
Opis bibliograficzny
Modelowanie zjawiska ferrorezonansu w sieciach elektroenergetycznych — Modeling and analysis of the ferroresonance phenomena in the electrical grid / Konrad KOCHANOWICZ, Wiesław NOWAK, Rafał TARKO // Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej ; ISSN 2353-1290. — Tytuł poprz.: Zeszyty Naukowe Wydziału Elektrycznego Politechniki Gdańskiej ; ISSN: 1425-5766. — 2017 — nr 57, s. 51–54. — Bibliogr. s. 54, Streszcz. — Zastosowanie komputerów w nauce i technice 2017 : XXVII cykl seminariów zorganizowanych przez PTETiS Oddział w Gdańsku = Application of computers in science and technology 2017 : proceedings of the XXVII Seminar organised by Polish Society of Theoretical and Applied Electrical Engineering PTETiS, Gdańsk Section
Autorzy (3)
Słowa kluczowe
Dane bibliometryczne
| ID BaDAP | 111291 |
|---|---|
| Data dodania do BaDAP | 2018-01-14 |
| Rok publikacji | 2017 |
| Typ publikacji | referat w czasopiśmie |
| Otwarty dostęp | |
| Czasopismo/seria | Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej |
Abstract
The ferroresonance phenomena in the power system is a significant problem in electric grid. The nonlinear vibration of the current and the voltage present a risk to the electrical apparatus. Due to the nonlinearity of that phenomena a classical analysis method are not applicable and digital methods of analysis are necessary. The article present a risk to the electrical apparatus. Due to the nonlinearity of that phenomena a classical analysis method are not applicable and digital methods of analysis are necessary. The article presents application of the EMTP-ATP program to determine simulation results. EMTP-ATP is a universal program system for digital simulation of transient phenomenon of electromagnetic. To analysis was subjected the 110kV double-circuit overhead lines with two different nonlinear elements – power transformer and voltage transformer. That types of circuit is one of the susceptible to ferroresonance oscillations. Computer simulations confirmed that theory. The oscillation were observed for the given configuration. The results of the simulation shows that a voltage transformer are particularly vulnerable to ferroresonance phenomenon.
Streszczenie
Zjawisko występowania drgań ferrorezonansowych w systemie elektroenergetycznym jest istotnym problemem w elektroenergetyce. W artykule przedstawiono badania symulacyjne możliwości wystąpienia ferrorezonansu w sieci 110 kV.