Szczegóły publikacji

Opis bibliograficzny

Microflow measurements of antibodies fluorescence using Silicon Photomultipliers / P. DOROSZ, M. BASZCZYK, S. GŁĄB, W. KUCEWICZ, Ł. MIK // W: 2014 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) [Dokument elektroniczny] : 8–15 Nov. 2014, [Seattle, USA]. — Wersja do Windows. — Dane tekstowe. — [Piscataway : IEEE], [2014]. — e-ISBN: 978-1-4799-6097-2. — S. [1–2]. — Wymagania systemowe: Adobe Reader. — Bibliogr. s. [2], Abstr. — Publikacja dostępna online od: 2016-03-14

Autorzy (5)

Słowa kluczowe

silicon photomultiplierantibody detectionfluorescent dye

Dane bibliometryczne

ID BaDAP103965
Data dodania do BaDAP2017-02-01
Tekst źródłowyURL
DOI10.1109/NSSMIC.2014.7431015
Rok publikacji2014
Typ publikacjimateriały konferencyjne (aut.)
Otwarty dostęptak
Konferencja2014 IEEE Nuclear Science Symposium and Medical Imaging Conference

Abstract

The paper presents research made using acquisition system designed and built by the authors. It consists of Silicon Photomultipliers used for fluorescence light detection, integrated circuit dedicated for Silicon Photomultipliers and FPGA board for data acquisition. Moreover, electronic part of the system is integrated with optical section i.e. semiconductor laser, optical filters, microflow structure and optical fibers. Measured substances are passed through Polydimethylsiloxane (PDMS) microflow structure with microchannel of tens of um diameter and that is where optical detection phase takes place. The substance is stimulated by laser light and its fluorescence is being detected by SiPM. Measurements with fluorescence dyes such as sodium fluoresceinate and BD Biosciences CF series indicate sensitivity of the measurement system on the level of single picogram of the dye in ml of the buffer. CF dyes are being mixed with antibodies such as ANTI-NPR in order to measure sensitivity of the system for various concentrations of the antibody. ANTI-NPR is an antibody that reacts with human natriuretic peptide, a substance that can be found in human blood short after excessive heart effort or heart failure. Measurement system is not designed only for NPR antibody but also e.g. myoglobin, troponin and others. That is why not only single antibody has been measured.

Publikacje, które mogą Cię zainteresować

fragment książki
#103967Data dodania: 1.2.2017
Front-end electronics with fast signal shaper for Silicon Photomultipliers / P. DOROSZ, M. BASZCZYK, S. GŁĄB, W. KUCEWICZ, Ł. MIK, R. Calabrese, A. Cotta Ramusino, E. Luppi, R. Malaguti // W: 2014 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) [Dokument elektroniczny] : 8–15 Nov. 2014, [Seattle, USA]. — Wersja do Windows. — Dane tekstowe. — [Piscataway : IEEE], [2014]. — e-ISBN: 978-1-4799-6097-2. — S. [1–3]. — Wymagania systemowe: Adobe Reader. — Bibliogr. s. [3], Abstr. — Publikacja dostępna online od: 2016-03-14
fragment książki
#96811Data dodania: 19.3.2016
STS-XYTER, a high count-rate self-triggering silicon strip detector readout IC for high resolution time and energy measurements / Krzysztof KASIŃSKI, Rafał KŁECZEK, Piotr OTFINOWSKI, Robert SZCZYGIEŁ, Paweł GRYBOŚ // W: 2014 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) [Dokument elektroniczny] : 8–15 Nov. 2014, [Seattle, USA]. — Wersja do Windows. — Dane tekstowe. — [Piscataway : IEEE], [2014]. — e-ISBN: 978-1-4799-6097-2. — S. [1–6]. — Wymagania systemowe: Adobe Reader. — Bibliogr. s. [5–6], Abstr.