Szczegóły publikacji

Opis bibliograficzny

Experimental confirmation of the reliability of Fanger’s thermal comfort model—case study of a near-zero energy building (NZEB) office building / Michał Piasecki, Małgorzata Fedorczak-Cisak, Marcin Furtak, Jacek Biskupski // Sustainability [Dokument elektroniczny]. — Czasopismo elektroniczne ; ISSN 2071-1050. — 2019 — vol. 11 iss. 9 art. no. 2461, s. 1-25. — Wymagania systemowe: Adobe Reader. — Bibliogr. s. 23–25, Abstr. — Publikacja dostępna online od: 2019-04-26

Autorzy (4)

Słowa kluczowe

PMVPPDpanel teststhermal comfortNZEBindoor environmental qualitythermal comfort model

Dane bibliometryczne

ID BaDAP122859
Data dodania do BaDAP2019-11-12
Tekst źródłowyURL
DOI10.3390/su11092461
Rok publikacji2019
Typ publikacjiartykuł w czasopiśmie
Otwarty dostęptak
Creative Commons
Czasopismo/seriaSustainability

Abstract

Designing and constructing near zero energy buildings (NZEBs) is a challenge not only from a structural point of view, but also from the point of view of ensuring appropriate climate comfort for users. The standards describing how to ensure comfort were created in times when the challenges of building ZEB/NZEB were not yet explored and energy issues were not as important as they are today. Therefore, the assessment of the thermal and climatic comfort of people living and working in such buildings requires a new or revised approach to the methodology of thermal comfort assessment. In this article, the authors present the results of a thermal comfort study based on measurements and thermal sensory tests. Testing was carried out in an experimental office building (passive standard). The main goal of the experiment was to compare the thermal comfort measurement method based on the ISO-Fanger model with the actual comfort results obtained by the panellists in the model office condition. The tests allowed the lowest operating temperature providing thermal comfort (predicted mean vote (PMV) = 0 and -0.5) to be determined. Sensory tests were conducted using three types of questions. The results were compared to the other researchers' findings. It was noted that the panellists showed better thermal comfort sensation at lower temperatures than would result from the traditional Fanger distribution, so the authors proposed the experimental function of percentage of dissatisfied (PPD) = f(PMV). The authors hope that it contributed to the actual state of knowledge as a "small and specific scale" validation of the existing thermal comfort model. The results also revealed that the method of heating has an influence on the subjective thermal sensation. © 2019 by the authors.

Publikacje, które mogą Cię zainteresować

artykuł
#139677Data dodania: 1.4.2022
An experimental study of thermal comfort and indoor air quality — a case study of a hotel building / Marek BOROWSKI, Klaudia ZWOLIŃSKA, Marcin Czerwiński // Energies [Dokument elektroniczny]. — Czasopismo elektroniczne ; ISSN  1996-1073 . — 2022 — vol. 15 iss. 6 art. no. 2026, s. 1–18. — Wymagania systemowe: Adobe Reader. — Bibliogr. s. 16–18, Abstr. — Publikacja dostępna online od: 2022-03-10
artykuł
#140201Data dodania: 27.5.2022
Thermal network model for an assessment of summer indoor comfort in a naturally ventilated residential building / Piotr MICHALAK // Energies [Dokument elektroniczny]. — Czasopismo elektroniczne ; ISSN 1996-1073. — 2022 — vol. 15 iss. 10 art. no. 3709, s. 1–19. — Wymagania systemowe: Adobe Reader. — Bibliogr. s. 16–19, Abstr. — Publikacja dostępna online od: 2022-05-18